background image

18

17

SPECIFICATIONS

Temperature Measurement

Main unit

Indoor Temperature 

Proposed operating range

: -5

°

C to +50

°

C /

23

°

F to 122

°

F

Temperature resolution

: 0.1

°

C/ 0.2

°

F

Remote Sensor

Proposed operating range

with alkaline batteries

: -20

°

C to + 70

°

C /

-4 

°

F to 158

°

F

Proposed operating range

with lithium batteries

: - 38

°

F to 158

°

F

  ( -38.8 C

°

 to 70

°

C)

Temperature resolution

: 0.1

°

C/ 0.2

°

F

RF Transmission Frequency

: 433 MHz

Maximum number of remote sensors

: 3

RF Transmission Range

: Maximum 100 feet 

Temperature sampling cycle

: approximately

45 seconds

Calendar and Clock

12 hour display in hh : mm format

Date Format: Month – Day format

Day of week: User- selectable in 3 languages

(English, French, Spanish)

Dual 4-minute crescendo alarm with snooze

Pre-alarm for ice alert with programmable time intervals

Power

Main unit

  : 2 x UM-3/ AA (1.5V) batteries

    - alkaline are suggested (not included)

 

   : AC adapter (AC120V, 60Hz-DC5.0V, 100mA).

Remote Sensor : 2 x UM-3/ AA (1.5V) batteries

     - alkaline are suggested (not included)

    Lithium batteries are suggested (not included)

    at 32

°

F temperature and below

Dimensions

Main unit

  : 3.25(L) x 4.5(H) x 1.25(D) inches

Remote sensor : 2(L) x 4(H) x 1 (D) inch

FCC STATEMENT

This device complies with Part 15 of the FCC Rules.

Operation is subject to the following two conditions:

(1) This device may not cause harmful interference, and

(2) This device must accept any interference received,

      including interference that may cause undesired operation. 
Warning: Changes or modification to this unit not expressly

approved by the party responsible for compliance could void

the user’s authority to operate the equipment.
NOTE: This equipment had been tested and found to comply

with the limits for a Class B Digital device, pursuant to

Part 15 of the FCC Rules. These limits are designed to

provide reasonable protection against harmful interference

in a residential installation. This equipment generates, uses

and can radiate radio frequency energy and, if not installed and

used in accordance with the instructions, may cause harmful

interference to radio communications.
However, there is no guarantee that interference will not occur

in a particular installation. If this equipment does cause harmful

interference to radio or television reception, which can be

determined by turning the equipment off and on, the user is

encouraged to try to correct the interference by one

or more of the following measures:
Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment to an outlet on a circuit different

from that to which the receiver is connected.

Consult the dealer or an experienced radio / TV technician

for help.

Содержание PCR325W

Страница 1: ...1 1 Wireless Weather Projection Clock with Light Detector USER MANUAL PCR325W ...

Страница 2: ...display Multi channel capability to monitor temperature in up to three remote locations additional sensors required Outdoor temperature Barometric pressure with three trend indicators Rising Steady Falling Weather forecast in five large graphic icons Sunny Partly Cloudy Cloudy Light Rain and Heavy Rain Current time and remote temperature projected onto the wall or ceiling in bright red digits Prec...

Страница 3: ...three different alarm modes Sets the weekday alarm single alarm or pre alarm D MODE BUTTON Toggles between the clock modes the time with the seconds and the time with the day of week Sets the clock manually E LIGHT SNOOZE BUTTON Activates the snooze feature backlight and projection F DOWN BUTTON Decreases the setting G UP BUTTON Increases the setting H BATTERY COMPARTMENT Holds two AA batteries I ...

Страница 4: ... remote temperature will appear on the receiver s display position the remote sensor and main unit within the effective transmission range of 100 feet NOTE 1 Avoid setting the time and date on the main unit before the outdoor temperature is displayed 2 The effective operating range may be influenced by the surrounding building materials and how the receiver and transmitter are positioned A LED IND...

Страница 5: ...inutes a dashes will be displayed Hold button for 2 seconds to enforce an immediate search If no signals are received from the remote sensor s within 2 minutes dashes will be displayed Press and hold DOWN button for 2 seconds to activate another signal search BATTERY INSTALLATION REMOTE SENSOR NOTE Install the batteries select the channel and type of temperature ºC ºF before you mount the sensor 1...

Страница 6: ... miles away Due to the nature of the Earth s ionosphere reception can be limited during the daylight hours The radio controlled clock will search for an alternate station that derives its signal from the NIST Atomic clock in Boulder Colorado The WWVB tower icon on the main unit s display will flash indicating radio signal reception from the WWVB station If the tower icon is not fully lit or if the...

Страница 7: ... Use lithium ion batteries at the temperatures below 32 F NOTE 1 The weather forecast accuracy is approximately 70 2 Display shows forecasted not current conditions 3 The Sunny icon indicates clear weather even when displayed during nighttime hours BAROMETRIC PRESSURE The barometric pressure arrows indicate if pressure is rising steady or falling INDOOR ANR OUTDOOR TEMPERATURES The trend indicator...

Страница 8: ...inutes the time signal has not been received press the MODE button to set the time manually The clock will continue to search for the WWVB time signal daily from 1 00 am to 4 30 am When the signal has been successfully received the time and date will be updated automatically MANUAL SETTINGS TIME ZONE 1 Press MODE to select the time with the day of week display mode 2 Select the time zone by pressi...

Страница 9: ...e warranty and may cause damage These units contain no user serviceable parts 5 Use only fresh batteries Do not mix new and old batteries 6 Read the user s manual thoroughly before operating the units SETTING THE ALARM To set any alarm 1 Press ALARM ON OFF once to display a specific alarm time If the selected alarm is off OFF will be displayed 2 Press and hold ALARM ON OFF for 2 seconds The hour d...

Страница 10: ...o the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation Warning Changes or modification to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment NOTE This equipment had been tested and f...

Страница 11: ...over damages or wear resulting from accident misuse abuse commercial use or unauthorized adjustment and repair Note that online product registration is required to ensure valid warranty protection To register your product go to our Company website at www hidekielectronics us Click Online Product Registration under the Customer Service menu Should you require assistance with this product and its op...

Отзывы: