8
ASSEMBLING THE RESPIRATOR
To use this full facepiece as an air-purifying respirator, you need to attach a filter, cartridge or
cartridge/filter combination. Follow the directions below for the filter or cartridge type you are using.
1.
If you are using a pad style filter only, you will need P/N N750037 (includes two
N750027 covers and two N750015 filter holders) in addition to the two filters.
a)
Place each filter into the filter cover, paying attention to the instructions on the
filter “this side towards face” or “this side away from face” (Figure 1).
b)
Snap the filter cover and filter onto the filter holder (Figure 2). Proceed to Step 5.
2.
If
you are using a pair of pad style filters (either 7506N95, 7506R95 or 7506N99) with
a gas or vapor cartridge, you will need P/N N750036 (includes two N750027 filter
covers and two N750038 filter supports) in addition to the two filters. Ensure the pad
filters are the same type to provide proper protection.
Figure 1
Figure 2
S1 -
SPECIAL OR CRITICAL USER’S INSTRUCTIONS
Honeywell N-Series gas and vapor cartridges require the use of a filter support (P/N N750038) when a pad style filter is used with the
cartridge. Failure to follow this instruction will result in the risk of serious illness, injury or death.