12
5. Infrared
Port:
The infrared port is located
next to the MODE button on the front face
of the instrument. The infrared port is
used for communications between the
MultiPro and a PC.
6. On / Off "MODE" button:
The large black
push-button on the front of the instrument
is called the "MODE" button. The MODE
button is used to turn the MultiPro on and
off as well as to control most other
operations, including the automatic
calibration adjustment.
7. Sensor compartment cover:
The
sensors are located in a vented
compartment at the bottom of the
instrument.
8. Audible alarm port:
A cylindrical port
extending through the front of the
instrument just above the display houses
the loud audible alarm. The waterproof
audible alarm seats directly to the rubber
inner-liner to protect the instrument
against leakage or exposure to liquids.
9. Battery
pack:
Two types of
interchangeable battery packs
(rechargeable Lithium Ion (Li-Ion) and
disposable alkaline) are available for use.
Li-Ion battery packs may be recharged
while the pack is installed in the
instrument, or removed from the
instrument for separate recharging.
10. Battery charger connector:
A water-
resistant connector at the bottom of the
case assembly is used to connect the
MultiPro to the “drop in” style charger.
11. Back surface:
A sturdy clip allows the
user to wear the MultiPro on a belt or
other article of clothing.
1.10 MultiPro standard accessories
Standard accessories included with every
MultiPro include calibration adapter, additional
tubing for use during calibration, reference
manual and quick reference card.
The optional manual sample draw kit consists
of a sample draw / calibration adapter,
squeeze bulb, standard sample probe,
replacement sample probe filters, and ten feet
of tubing. The sample probe itself is also
available separately.
Standard configurations of the MultiPro are
delivered in a cardboard box with cardboard
inserts.
1.10.1 Alkaline MultiPro detectors
If the MultiPro has been purchased as an
alkaline instrument, the standard accessories
include a set of 3 disposable AA alkaline
batteries.
1.10.2 Li-Ion MultiPro detectors
If the MultiPro has been purchased as a Li-Ion
rechargeable instrument, the standard
accessories include Li-Ion battery pack and a
slip-in MultiPro charger.
1.11 MultiPro
kits
MultiPro detectors may also be purchased as
part of a complete kit that includes calibration
gas, fixed-flow regulator and a hard-shell
carrying case.
1.11.1 MultiPro Confined Space Kits
In addition to the standard accessories listed
above, Confined Space Kits also include
calibration fittings, fixed-flow regulator with
pressure gauge, and appropriate large
cylinder of calibration gas in a foam-lined,
waterproof hard-shell carrying case.
1.11.2 MultiPro Value Packs
MultiPro Value Packs include an alkaline
MultiPro, all standard accessories, calibration
fittings, small cylinder(s) of calibration gas,
and fixed flow regulator in a foam-lined non-
waterproof hard-shell carrying case.
2. Basic
Operations
The MultiPro is a true one-button gas
detector. The MODE button is located on the
front of the instrument and controls all field-
level operations including the following
Turning the MultiPro on and off
Turning on the backlight
Viewing the MAX, STEL and TWA reading
screens
Initiating the calibration sequence
2.1 Turning the MultiPro On
To turn the MultiPro on, press and hold the
MODE button for one second. The first
screen shown will be the test screen for the
LCD. All sections should be darkened. The
test screen will be followed by a screen
showing the instrument firmware version. “dL”
will appear in the upper right for instruments
with a fully enabled datalogger.
→
Содержание MultiPro