LYNX Touch Installation and Setup Guide
- 58 -
System Operation
Event Log
The LYNX Touch Series event log is capable of recording and displaying up to 128 system events. The type
of events that can be recorded is selectable and is programmed in the System Type programming field. The
event log can be reviewed by entering the Installer Programming or Master User Programming mode. Refer
to the LYNX Touch Series User Manual for additional information.
Note: In the unlikely condition that the backup battery becomes fully discharged when AC power is lost, any system activity performed after
the low battery notification will not be saved in the event log. Additionally, the panel will revert to the status condition as before the low
battery notification.
Contact ID® & SIA Event Log Codes
CID
Code
Definition
SIA
Code
Definition
110 Alarm,
Fire
AT/AR AC
Trouble/AC
Restoral
121 Alarm,
Duress
BA/BR
Burglary Alarm/Burglary Restoral
122 Alarm,
Silent
CA/CD
Automatic Closing/Closing Delinquent
123 Alarm,
Audible
CI
Fail to Close (Log only)
131 Alarm,
Perimeter
CL
Closing
Report
132 Alarm,
Interior
CQ
Remote
Closing
134 Alarm,
Entry/Exit
CR
Recent
Closing
135 Alarm,
Day/Night
DF/DR
Door Forced/Door Restoral
137 Alarm,
Tamper
EA
Exit
Alarm
145
Expansion Module Tamper
ES/EJ
Expansion Device Tamper/Expansion Tamper Restore
146 Silent
Burglary
ET
Expansion
Trouble
150 24-Hour
Non-Burglary
FA
Fire
Alarm
162
Carbon Monoxide Detected
FT/FJ
Fire Trouble/Fire Trouble Restore
301
Trouble, AC Loss
HA/HR
Holdup Alarm/Holdup Restoral
302
Trouble, Low System Battery
GA/GR Gas
Alarm/Gas
Restoral
305
Trouble, System Reset
FT/FJ
Fire Trouble/Fire Trouble Restore
316
System Tamper*
LT/LR
Phone Line Trouble/Phone Line Restoral
341
Trouble, Case Tamper
OA
Automatic Opening
344
Trouble, RF Receiver Jam Detect
OC
Cancel
Report
351
Trouble, Telco 1 Fault
OP
Opening
Report
353
Trouble, Long Range Radio Transmitter Fault
OQ
Remote
Opening
373
Trouble, Fire Trouble
PA
Panic
Alarm
374
Trouble, Exit Error Alarm
RP
Automatic
Test
380
Trouble, Sensor
RX
Manual Test
381
Trouble, Loss of Supervision RF
TA/TH
Tamper Alarm/Tamper Alarm Restore
383
Trouble, Sensor Tamper
TJ
Tamper Trouble Restore
384
RF Low Battery
TS/TE Test
Start/Test
End
401
Open/Close by User
TT
Tamper
Trouble
403 Open/Close
Automatic
UA
Untyped Zone Alarm
406 Cancel
UB/UU
Untyped Zone Bypass/Untyped Zone Unbypass
407 Remote
Arm/Disarm
UT/UJ
Untyped Zone Trouble/Restore
408 Quick
Arm
XG/XH
RF Interference/RF Interference Restore
441 Armed
Stay
XT/XR
Transmitter Battery Trouble/Transmitter Battery Restoral
455
Auto-Arm Failed
YT/YR
System Battery Trouble/System Battery Restoral
459 Recent
Close
570 Zone/Sensor
Bypass
601
Manual Trigger Test Report
602
Periodic Test Report
606
Listen-in to follow
607 Walk
Test
623
Event 90% Full
627
Program Mode Entry (Logged in Event Log Only)
628
Program Mode Exit (Logged in Event Log Only)
*If APL is enabled, AlarmNet will generate a special comm. fail
message (E316) if it does not hear from a unit within 15 minutes
after a delayed alarm is delivered. This message is meant to alert
the Central Station that the system has been tampered with and
may have been compromised.
654 System
Inactivity
655
Reset Master Code (Logged in Event Log Only)
759
Resident Monitor Zone Response
760
Resident Response Zone Response
761
General Monitor Zone Response
762
General Response Zone Response