LYNX Touch Installation and Setup Guide
- 41 -
Programming the Control
Note: If applicable, preprogrammed defaults for the LYNX Touch Control are shown on the screen unless otherwise noted.
SCREEN ACTION
System Settings
Select “System Settings”
The System displays the following options:
Entry Delay 1
Entry Delay 2
Exit Delay
Backlight Timeout
Quick Arm
Quick Exit
Restart Exit Time
Force Bypass
Exit Warning
Auto Stay Arming
Use the down
T
arrow to scroll to the next page of options. Use the
S
arrow to return to
the previous page:
Lack of Usage Notify
Power-Up In Previous
Display Alarm Cancel
Display Exit Time
Cross Zone Delay
Cross Zone 1
Cross Zone 2
Entry Delay 1
30 Seconds
Select “Entry Delay 1”. The System scrolls between the following options:
LYNX Touch
LYNX Touch (L5100CN) Canada
None None
15 Seconds
15 Seconds
30 Seconds
30 Seconds
45 Seconds
45 Seconds
60 Seconds
60 Seconds
90 Seconds
90 Seconds
2 Minutes
2 Minutes
3 Minutes
4 Minutes
UL installations: The Entry Delay must be set for a maximum of 45 seconds.
SIA: The Entry delay must be set to a minimum of 30 seconds. The sum of entry delay 1 and
the burglary abort window should not exceed 1 minute. “None” is only allowed for use
in Commercial High-Security applications.
Entry Delay 2
30 Seconds
Select “Entry Delay 2”. The System scrolls between the following options:
LYNX Touch
LYNX Touch (L5100CN) Canada
None None
15 Seconds
15 Seconds
30 Seconds
30 Seconds
45 Seconds
45 Seconds
60 Seconds
60 Seconds
90 Seconds
90 Seconds
2 Minutes
2 Minutes
3 Minutes
4 Minutes
UL installations: The Entry Delay must be set for a maximum of 45 seconds.
SIA: The Entry delay must be set to a minimum of 30 seconds. The sum of entry delay 1 and
the burglary abort window should not exceed 1 minute. “None” is only allowed for use
in Commercial High-Security applications.
Exit Delay
60 Seconds
Select “Exit Delay”. The System toggles between the following options:
LYNX Touch
LYNX Touch (L5100CN) Canada
45 Seconds
None
60 Seconds
15 Seconds
90 Seconds
30 Seconds
2 Minutes
45 Seconds
60
Seconds
90
Seconds
2
Minutes
UL installations: Exit Delay must be set for a maximum of 60 seconds
SIA: The Exit Delay must be set to a minimum of 45 seconds.
Backlight Timeout
No
Select “Backlight Timeout”. The System toggles between No and 30 Seconds.