Safety

Please read and keep in a safe place

 Please read through these instructions 

carefully before installing or operating. Following the 
installation, pass the instructions on to the opera-
tor. This unit must be installed and commissioned 
in accordance with the regulations and standards 
in force. These  instructions can also be found at 
www.docuthek.com.

Explanation of symbols
 • ,   ,   ,   

... = Action

 

= Instruction

Liability

We will not be held liable for damage resulting from 
non-observance of the instructions and non-com-
pliant use.

Safety instructions

Information that is relevant for safety is indicated in 
the instructions as follows:

 DANGER

Indicates potentially fatal situations.

 WARNING

Indicates possible danger to life and limb.

 CAUTION

Indicates possible material damage.

All interventions may only be carried out by qualified 
gas technicians. Electrical interventions may only be 
carried out by qualified electricians.

Conversion, spare parts

All technical changes are prohibited. Only use OEM 
spare parts.

Contents

Operating instructions

D

GB

F

NL

I

E

GB-1

05598

Translation from the German

Bus module BCM 400..B 

 PROFIBUS for BCU 4xx

Bus module BCM 400..B PROFIBUS 

for BCU 4xx. . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Contents  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Checking the usage . . . . . . . . . . . . . . . . . . . . . 
Installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Replacement. . . . . . . . . . . . . . . . . . . . . . . . . . . 

Wiring  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Commissioning. . . . . . . . . . . . . . . . . . . . . . . . . 
Assistance in the event of malfunction  . . . . . 5

Technical data  . . . . . . . . . . . . . . . . . . . . . . . . . 6

Logistics  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Contact  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Safety

Contents

Содержание Kromschroder BCM 400 B1 Series

Страница 1: ...ctions Information that is relevant for safety is indicated in the instructions as follows DANGER Indicates potentially fatal situations WARNING Indicates possible danger to life and limb CAUTION Indicates possible material damage All interventions may only be carried out by qualified gas technicians Electrical interventions may only be carried out by qualified electricians Conversion spare parts ...

Страница 2: ...tandard communication SafetyLink B1 B2 B3 B4 PROFIBUS DP PROFINET EtherNet IP Modbus TCP 1 3 9 pin D Sub Two RJ45 sockets 0 3 Three point step control via bus Part designations 3 4 1 2 1 BCM 1 with 9 pin D Sub connection 2 9 pin D Sub connection 3 Code switches 4 Type label Ambient temperature A B see type label Elster GmbH Osnabrück Made in Germany A B Installation 1 Disconnect the BCU from the e...

Страница 3: ... and software can be downloaded from www docuthek com 1 Set parameter A080 2 Fieldbus communica tion without address check 2 Check the code switch settings 001 to 125 on the BCM for PROFIBUS communication between BCSoft and the control unit Each code switch setting combination may only exist once within the fieldbus system Each device name network name may only be allocated once within the fieldbu...

Страница 4: ...P 4 ϑ2 5 Reserved 6 Reserved 7 Reserved P A A P DI on on on 1 2 Operating signal pilot burner P A A P DI on on on 1 2 Operating signal main burner P A A P DI on on on 1 2 Fault signal P A A P DI on on on 1 2 Operating signal air actuator P A A P DI on on on 1 2 Purge operating signal P A A P DI on on on 1 2 High temperature operation P A A P DI on on on 1 2 Ready for operation P A A P DI on on on ...

Страница 5: ...missioning If the transfer rate is reduced remember that this will increase the signal running times to and from the individual units Poor shielding Check whether the shield is connected to the shield clips in the PROFIBUS DP plugs in full and over a wide area Poor equipotential bond Check whether the PROFIBUS DP shield is con nected at all points to the same ground potential via the grounding sys...

Страница 6: ... location min IP 65 for installation in BCU 4xx Permitted operating altitude 2000 m AMSL Mechanical data Dimensions W H D 96 63 23 mm 3 78 2 48 0 91 inch Weight 0 3 kg Electrical data Power consumption 1 2 VA Power loss 0 7 W Designed lifetime Max service life under operating conditions 10 years after date of production Logistics Transport Protect the unit from external forces blows shocks vibrati...

Отзывы: