11. Maintenance and Servicing
11.1Maintenance
In accordance with DIN 1988, part 8; the following
measures must be taken:
11.2Block Salt Level
1. Remove the covering cap from the cabinet.
2. Check the level in the cabinet.
3. The salt level has fallen below 3 cm (lower casing
edge). Refill block salt (
☞
Chapter 7.2).
4. Attach the salt lid.
Replace the covering cap on the cabinet.
11.3Cleaning
1. Set the water conditioning device to "Bypass".
2. Remove the covering cap from the cabinet.
3. Remove the salt lid from the cabinet.
4. Check the inner and outer brine tube for contami-
nation and salt deposits.
5. Clean the inner and outer parts with water and a
cloth.
6. Attach the salt lid.
7. Check the inner and outer cabinet for contaminati-
on and salt deposits.
8. Clean the inner and outer parts with water and a
cloth.
9. Replace the covering cap on the cabinet.
10. Set the water conditioning device to "Bypass".
12. Disposal
Das Waserbehandlungsgerät besteht aus:
• Brass
• Steel
• Plastic
CAUTION!
Maintenance work should only be carried out be
qualified staff!
i
Plant for single-family houses
interval: annually
i
Plant for apartment blocks, public institutions
interval: every 6 months
i
Interval: every 6 months (depending on local
conditions)
Carried out by an installation company
Carried out by the operator
CAUTION!
To clean parts made of synthetic material do not
use detergents containing solvents!
Detergents must not be allowed to enter the
environment or the sewerage system!
Observe the local requirements regarding cor-
rect waste recycling/disposal!