Honeywell GmbH
13
MU1H-1417GE23 R1114
GB
13. Troubleshooting
14. Spare Parts
15. Accessories
Problem
Cause
Remedy
No water supply to the device
Shut-off device in the bypass is not open or
only partially open
Open shut off valve fully
Pipework of the drinking water supply is
calcified or blocked
Clean or replace the pipework
Device does not regenerate
Flow meter is defective
Check and, if necessary, replace the flow
meter (CS*)
Internal electric cabling is defective
Check internal electric cabling (CS*)
Wrong connection of connecting hoses
Connect the flexible connection lines
correctly
Rotary disc valve defective
Call Technical Customer Service
Nothing is displayed
Power supply has been interrupted
Check power suppy (mains plug, fuse)
Rotary disc valve defective
Call Technical Customer Service
Incorrect time is displayed
Power failure occurred
Set the time
Insufficient function
Device not deaerated
Deaerate device
Storage tank is almost or completely empty Check salt level
Blending has been set incorrectly
Check blending valve and mixing ratio
Control valve is contaminated or defective Call Technical Customer Service
*CS = Customer services tel. 0 18 01 - 46 63 88
No. Description
Part No.
1
Disinfection unit
DE10S-A
2
Disinfection unit
for devices produced from August
2013 onwards
DE10S-AN
3
Controller head seal kit
EK10S-A
4
Spare part kit for brine pump
EK10S-B
5
O-ring set
EK10S-C
6
Turbine water counter
EK10S-D
7
Bypass/blending valve for KS10S
BV10S-A
8
Stainless steel corrugated pipe for
KS10S
CP10S-A
9
Transformer KS10S
TR10S-A
10
Control panel for KS10S
CE10S-A
D06F
Pressure reducing valve
Noise protected pressure reducing valve with
setting scale. Maximum inlet pressure 16 bar,
with brass filter bowl 25 bar, outlet pressure
range 1.5 - 6.0 bar
A = With clear filter bowl up to 40 °C / 16 bar
B = With brass filter bowl up to 70 °C / 25 bar
F76S
Fine filter, reverse rinsable
AA= With clear filter bowl
AAM= With red bronze filter bowl
OFV10S-A Bypass valve insert
if a pressure scourer is applicated it is necces-
sary to fit a bypass valve insert into the bypass
valve.
Содержание KaltecSoft KS10S-30