Configuring Camera Settings Using the OSD  |  23

800-21699 - A - 04/2016

PATTERN

Move the cursor to PATTERN and click the confirm button to go to the submenu, where you can 
view or modify the following settings:

Note

The dwell time between two commands should be less than one minute, otherwise 
the system will set the default value as one minute. After selecting SETTING STOP, do 
not use the CALL function until the "?" icon completely disappears. Any manual PTZ 
control inputs during a pattern procedure will cause it to stop running.

IDLE MOTION

Move the cursor to IDLE MOTION and click the confirm button to go to the submenu, where you 
can view or modify the following settings:

AUTO RUN (SCHEDULE TASK)

Move the cursor to AUTO RUN and click the confirm button to go to the submenu, where you 
can view or modify the following settings:

• PATTERN NO

Sets the pattern number. Click the left/right button to set.

• SETTING

At the prompt, begin the pan/tilt/zoom operations that you 
want the system to memorize as a pattern.

• SETTING STOP

To stop memorizing a pattern, move the cursor to SETTING 
STOP, and then click the confirm button. 

• CALL

Input the pattern number, move the cursor to CALL, and then 
click the confirm button to begin running the pattern.

• STOP

Move the cursor to STOP and click the confirm button. The 
current pattern stops running.

• IDLE ACTION

The camera will execute the preset action if it didn't receive any 
valid command during set time. 

• IDLE TIME

Sets the idle time. Click the left/right button to set.

• ACTION TYPE

Options include: NONE, PRESET, SCAN, TOUR, and 
PATTERN. Click the left/right button to set.

• SN

Sets the idle motion SN. System can implement the 
corresponding action when it is idle for the specified period. 
Click the left/right button to set.

• TASK NO

Sets the task number. Click the left/right button to set.

• TIME TASK

Sets the time task ON/OFF. Click the left/right button to set. 

• TASK SETTING

Sets the task begin time, end time, action type, and so on. See 
below for more details.

• TASK INFORMATION Select the confirm button to view task information.
• DELETE TASK

Input the task number, move the cursor to DELETE TASK, and 
then click the confirm button.

Содержание HDZ302LIK

Страница 1: ...this and other equIP Series IP camera documents on the Honeywell Video website Go to http www honeywellvideo com products cameras ip index html to find your camera and view download the latest documentation Refer to the Honeywell Open Technology Alliance to learn more about our open and integrated solutions go to http www security honeywell com hota ...

Страница 2: ...Revisions Issue Date Revisions A 04 2016 New document ...

Страница 3: ...etworks Important note regarding PoE operation of models HDZ302LIW HDZ302LIK A high power PoE injector capable of supplying at least 60 W is required for proper operation of outdoor camera models HDZ302LIW HDZ302LIK Using PoE IEEE802 3af or IEEE802 3at will not support these models WARNING To comply with EN50130 4 requirements a UPS should be employed when powering the camera from 24 V AC WARNING ...

Страница 4: ...liance Statement This Class A digital apparatus complies with Canadian ICES 003 Cet appareil numérique de la Classe A est conforme à la norme NMB 003 du Canada Manufacturer s Declaration of Conformance The manufacturer declares that the equipment supplied with this guide is compliant with the European Parliament and Council Directive on the Restrictions of the use of certain Hazardous Substances i...

Страница 5: ... as they may result in the risk of fire electric shock or injury to persons 7 ACCESSORIES Only use accessories specified by the manufacturer 8 CLEANING Do not use liquid cleaners or aerosol cleaners Use a damp cloth for cleaning 9 SERVICING Do not attempt to service this unit yourself Refer all servicing to qualified service personnel 10 REPLACEMENT PARTS When replacement parts are required be sur...

Страница 6: ...his product from other household type waste the volume of waste sent to incinerators or landfills will be reduced and thus natural resources will be conserved The UL compliance logo This logo indicates that the product has been tested and is listed by UL formerly Underwriters Laboratories The RCM compliance symbol This symbol indicates that the product conforms with the Australian RCM guidelines T...

Страница 7: ... Camera from a Browser 14 Before You Begin 14 Logging in to the Web Client 15 Installing the Honeywell Webplugin 16 Understanding the Web Client Interface 16 2 Configuring Camera Settings Using the OSD 17 Opening the OSD Menu 17 OSD Menu Operation 18 OSD Menu Overview 18 System Settings 19 Display Settings 20 Function Settings 21 Appendix A OSD Default Settings 27 Appendix B Web Client Default Set...

Страница 8: ...www honeywell com security 8 HDZ IR Series OSD Configuration Guide ...

Страница 9: ...ell Viewer web client Chapter 2 Configuring Camera Settings Using the OSD describes how to access and navigate the OSD menu and provides guidance on configuring OSD settings Appendix A OSD Default Settings lists the OSD menu settings and their defaults Appendix B Web Client Default Settings list the Honeywell Viewer web client settings and their defaults Appendix C Special Presets lists special pr...

Страница 10: ...www honeywell com security 10 HDZ IR Series OSD Configuration Guide ...

Страница 11: ...mera from a Browser on page 14 Understanding the Web Client Interface on page 16 Starting the IPC Tool To start the IPC Tool double click the IPC Tool icon The IPC Tool utility opens If Windows Security Alert appears 1 Select the check boxes for all three types of networks and then click Allow access 2 Click Refresh to refresh the IPC Tool ...

Страница 12: ...to Control Panel System and Security Windows Firewall Allow a program or feature through Windows Firewall and then click Allow another program 2 In the Add a Program dialog box click Browse 3 Navigate to the location of the IPCTool exe file select it and then click Open IPC Tool is added to the list of programs in the Add a Program dialog box ...

Страница 13: ... IPCTool exe and then click Add 5 In the Allowed programs and features list select IPCTool exe select the check boxes for Domain Home Work and Public and then click OK 6 Restart the IPC Tool to apply the settings IPC Tool Start Page The layout of the IPC Tool start page is shown below ...

Страница 14: ...gs The procedure for installing ActiveX in Internet Explorer is provided below The steps will be slightly different if you are using a different browser Firefox Chrome and Safari browsers are also supported CAUTION ActiveX can provide great interactive features but also brings the risk of allowing viruses and other unwanted malware onto your computer Be aware of this risk before enabling ActiveX s...

Страница 15: ...ipt ActiveX controls marked safe for scripting Note The ActiveX items to be enabled may vary depending on the version of Internet Explorer that you are using 6 Click OK to confirm the settings and then click OK again 7 Restart Internet Explorer for the new settings to take effect To restore the default security settings 1 Open Internet Explorer 2 Click the gear icon or Tools menu and then click In...

Страница 16: ...r Right click the information bar and then click Allow ActiveX control 2 The Security Warning window will appear Click Install to start the Honeywell webplugin software installation 3 After the installation has completed click Finish to close the installation window Note If your browser doesn t allow the Honeywell webplugin to install check your Internet security settings and ensure that ActiveX c...

Страница 17: ...on on page 18 OSD Menu Overview on page 18 System Settings on page 19 Display Settings on page 20 Function Settings on page 21 Opening the OSD Menu To access the camera s OSD menu from the web client in the Live window click Menu located in the lower panel at the right of the screen and then click Open You can also access the camera s OSD menu using Preset 90 ...

Страница 18: ...ttons to move the cursor within the OSD menu and click the left right buttons to change menu settings Click the center button to go to a submenu or confirm a selection alternatively you can click Iris in the PTZ Control panel OSD Menu Overview The following diagram illustrates the overall structure of the HDZ IP PTZ OSD menu ...

Страница 19: ...ettings SET NORTH Sets the benchmark north so that you can know the angle between the benchmark and the PTZ s current position Move the cursor to the option and click the confirm button The OK message appears Now north is set LANGUAGE Sets the OSD menu language Click the left right button to set FACTORY DEFAULT Restores the factory default settings Move the cursor to the option and click the confi...

Страница 20: ...set POSITION Sets whether or not the angle between benchmark north and the PTZ s current position is displayed Click the left right button to set ZOOM DISP Sets whether or not the optical zoom speed is displayed Click the left right button to set INSIDE TEMP Sets whether or not the camera s internal temperature is displayed There are three options C F OFF Click the left right button to set PATTERN...

Страница 21: ... confirm button to go to the submenu where you can view or modify the following settings PRESET NO To change the preset number click the left right button Different protocols support different preset values TITLE The system automatically creates a title for the camera To modify it click the left right button SETTING After you have enabled the preset title function in DISPLAY SETTING PRESET TITLE i...

Страница 22: ...an STOP Move the cursor to STOP and click the confirm button Auto scan stops TOUR NO Sets the tour number Click the left right button to set TOUR SETTING Move the cursor to TOUR SETTING and click the confirm button Here you can add or remove presets and set the corresponding dwell time and call speed DWELL Click the left right button to set the dwell time SPEED Click the left right button to set t...

Страница 23: ...ystem to memorize as a pattern SETTING STOP To stop memorizing a pattern move the cursor to SETTING STOP and then click the confirm button CALL Input the pattern number move the cursor to CALL and then click the confirm button to begin running the pattern STOP Move the cursor to STOP and click the confirm button The current pattern stops running IDLE ACTION The camera will execute the preset actio...

Страница 24: ...ou completed the setup click the confirm button to exit end time setup move the cursor to SAVE and then click the confirm button ACTION TYPE Options include tour scan preset and pattern Click the left right button to set ACTION NO The serial number of the scheduled task The number here may vary due to different action types SAVE After making changes move the cursor to SAVE and click the confirm bu...

Страница 25: ...when there is no command for the specified time It includes various setups Click the left right button to set PTZ CORRECTION Sets self diagnosis correction to ON or OFF any changes will take effect after the camera reboots Click the left right button to set PASSWORD Set to ON to enable password protection Click the left right button to set The function is on by default after you set a password SET...

Страница 26: ...www honeywell com security 26 HDZ IR Series OSD Configuration Guide ...

Страница 27: ...BR 9600 PARITY NONE VERSION 2 05 49 RHIRFOC ADDR INFORMATION ADDR TYPE SOFT ADDR SOFT 1 SET NORTH LANGUAGE ENGLISH ENGLISH FACTORY DEFAULT CAMERA RESTART DISPLAY SETTING PRESET TITLE ON AZIMUTH DISP OFF POSITION OFF ZOOM DISP OFF INSIDE TEMP OFF PATTERN DISP ON RS485 DETECT ON FUNCTION SETTING PRESET PRESET NO 1 1 300 TITLE PRESET 1 SETTING CALL AUTO PAN PAN SPEED 5 1 8 RUN STOP AUTO SCAN AUTO SCA...

Страница 28: ...TOP PATTERN PATTERN NO 1 1 5 PROGRAM START PROGRAM STOP CALL STOP IDLE MOTION IDLE FUNCTION OFF IDLE TIME 10MIN 0 999MIN IDLE ACTION NONE NONE PRESET SCAN TOUR PATTERN PARAMETER NONE AUTO RUN TASK NO 1 TIME TASK TASK SETTING WEEK ALL WEEK START TIME 00H 00M END TIME 00H 00M RUN ACTION PRESET SCAN TOUR PATTERN PARAMETER TASK INFORMATION DELETE TASK 1st Level 2nd Level 3rd Level 4th Level Default Se...

Страница 29: ...PERTIES WB AUTO AUTO EXPOSURE AUTO AUTO AE RECOVERY 15 MIN 2DNR OFF 3DNR OFF GENERAL 3DNR ON TNF INTENSITY 50 SNF INTENSITY 50 BACKLIGHT WDR CLOSE HLC CLOSE BLC CLOSE DAY NIGHT TYPE ICR DAY NIGHT PHOTORESISTOR FOCUS ZOOM DIGITAL ZOOM OFF ZOOM SPEED 8 FOCUS MODE SEMI AUTO FOCUS LIMIT 5 M SENSITIVITY DEFAULT AF TRACE OFF IR CORRECTION AUTO PICTURE HUE 50 BRIGHTNESS 50 CONTRAST 50 SATURATION 50 CHROM...

Страница 30: ... 60 SVC 1 OFF WATERMARK TEXT DIGITAL CCTV SUB STREAM 1 2 STREAM TYPE GENERAL FORMAT H 264 RESOLUTION 1080P FPS 30 BITRATE TYPE CBR BITRATE 384 I FRAME INTERVAL 60 SNAPSHOT SNAPSHOT SNAPSHOT TYPE GENERAL IMAGE SIZE 1080P QUALITY 5 INTERVAL 1 S OVERLAY PRIVACY MASK PRIVACY MASK 1 CHANNEL TITLE CHANNEL TITLE ENABLE TIME TITLE TIME TITLE ENABLE OSD INFO OSD INFO DISABLE PICTURE OVERLAY PICTURE OVERLAY...

Страница 31: ...P IP TCP IP HOSTNAME IPDome ETHERNET CARD WIRE MODE DHCP ENABLE ARP PING ON CONNECTION CONNECTION MAX CONNECTION 20 TCP PORT 37777 UDP PORT 37778 HTTP PORT 80 RTSP PORT 554 HTTPS PORT 443 CONNECTION ONVIF LOGIN AUTHENTICATION ENABLE PPPOE PPPOE OFF DDNS DDNS DDNS OFF SERVER TYPE HONEYWELL DDNS IP FILTER IP FILTER OFF SMTP SMTP OFF UPNP UPNP OFF SNMP SNMP OFF BONJOUR BONJOUR ENABLE MULTICAST MULTIC...

Страница 32: ...UDIO DETECT ENABLE DISABLE STORAGE SETUP SCHEDULE RECORD SCHEDULE GENERAL ON MOTION ON ALARM ON SNAPSHOT SCHEDULE GENERAL ON MOTION ON ALARM ON HOLIDAY SCHEDULE ENABLE OFF DESTINATION PATH LOCAL ENABLE ALL FTP OFF LOCAL LOCAL DISABLE FTP FTP DISABLE RECORD CONTROL RECORD LENGTH RECORD LENGTH 30 PRE EVENT RECORD PRE EVENT RECORD 5 DISK FULL DISK FULL OVERWRITE RECORD MODE RECORD MODE AUTO RECORD ST...

Страница 33: ... OFF ACCOUNT ADMIN ADMIN ADMIN GROUP ADMIN ADMIN GROUP GROUP USER USER GROUP PTZ SETTINGS ANALOG PTZ ADDRESS 1 BAUD RATE 9600 DATA BITS 8 STOP BITS 1 PARITY NONE AUTO MAINTAIN AUTO MAINTAIN AUTO REBOOT OFF AUTO DELETE OLD FILES OFF INFORMATION ONLINE USER ONLINE USER CURRENT USER 1st Level 2nd Level 3rd Level 4th Level Default Setting ...

Страница 34: ...www honeywell com security 34 HDZ IR Series OSD Configuration Guide ...

Страница 35: ...Preset Preset Call Function 1 to 79 Normal preset operation 80 Run Auto Pattern 1 81 Run Auto Pattern 2 82 Run Auto Pattern 3 87 Run Auto Tour 1 88 Run Auto Tour 2 89 Run Auto Tour 3 90 Open OSD Menu 92 Toggle Auto Iris AUTO IRIS 93 Toggle BLC ON OFF 94 Toggle D N Mode DAY NIGHT 97 Toggle IR ON OFF 98 PTZ Reset Preset Preset Call Function 99 Toggle EIS ON OFF 100 Toggle Defog AUTO OFF 101 Toggle A...

Страница 36: ...www honeywell com security 36 HDZ IR Series OSD Configuration Guide ...

Страница 37: ......

Страница 38: ...well com security de 49 0 7431 801 0 Honeywell Security France Immeuble Lavoisier Parc de Haute Technologie 3 7 rue Georges Besse 92160 Antony France www honeywell com security fr 33 0 1 40 96 20 50 Honeywell Security Italia SpA Via della Resistenza 53 59 20090 Buccinasco Milan Italy www honeywell com security it 39 0 2 4888 051 Honeywell Security España Avenida de Italia n 7 2a planta C T Coslada...

Отзывы: