Log in and follow the on-screen prompts. At this time only activate the SIM
so signal strength may be checked. DO NOT register the communicator at
this time. Please have the following information available to activate the
SIM:
•
MAC number and MAC CRC (located on the box and inside the
communicator).
You may log out of the AlarmNet Direct website.
Once the communicator is installed and programmed, it must be Registered
with AlarmNet. Registering activates the account with AlarmNet and
enables the security system's control panel to send reports.
Verify Satisfactory Signal Strength
In this procedure you will temporarily power up the communicator to check
for satisfactory signal strength. You can power it from a 12V battery or from
the control panels AUX PWR terminals. In buildings where reception may be
a problem, powering from a battery would allow the communicator to be
portable. The following procedure assumes the control panel will be used for
power. (If satisfactory signal strength is present at the control panel that is
the preferred mounting location.)
1.
Ensure power to the control panel (both AC and battery) is off. Open
the enclosure and connect the ECP cable to the communicator.
Temporarily attach the Black and Red wires to the GND and AUX
PWR terminals of the control panel. DO NOT connect the Yellow
and Green wires at this time.
2.
Turn power on and wait about one minute for the communicator to
initialize. Position the communicator near a suitable mounting
position. Verify the SIGNAL LED (green) lights steady. This
indicates satisfactory signal strength.
Содержание GSMX4G