PROMPTS
ENTRY
OPTIONS
DESCRIPTION
The address used must also be
enabled as a 4204 relay module in
Vista and First Alert control
panels.
NOTE: Account information is provided by the central station administrator.
12
Primary City
ID
(??)_
[01-99]
Enter the 2-digit primary city ID,
01-99 (decimal).
13
Primary CS
ID
(??)
[01-FE]
Enter the 2-digit primary central
station ID number, 01-FE (HEX).
14
Primary Sub
ID
(????)
[0001-
9999]
Enter the 4-digit subscriber
account number, 0001-9999
(decimal).
15
En. 2nd CS
Y/N
(N)
[Y],
[N]
Applicable only if the control
panel supports Central Station #1
and #2 Category Enable reporting
for the communicator (or LRR)
device (e.g., VISTA-128BP,
FA1660C, etc.).
Used if reporting to a second
central station is desired.
16
Device
Address
(03)_
[01-30]
The GSMX4G communicates with
the control panel as a commu-
nicator (or LRR) device. Enter
the ECP device address.
NOTE:
When programming the
control panel, enable the commu-
nicator’s (or LRR) output.
Setting up the Remote Access Feature
Remote Access enables the user to control the security system using a web browser.
This feature must be configured at the AlarmNet Direct website as follows:
•
Remote Access must be enabled by selecting "Enabled" at the Remote Access
prompt.
•
A keypad address must be enabled in the communicator in order for it to commu-
nicate with the control panel.
•
At the “Keypad Type” prompt, select the appropriate Keypad.