11 - 3
This response indicates that the device’s Codabar Coding Enable (CBRENA) is set to 1, or on;
the Start/Stop Character (SSX) is set to 0, or Don’t Transmit;
the Check Character (CK2) is set to 0, or Not Required;
concatenation (CCT) is set to 1, or Enabled;
the Minimum Message Length (MIN) is set to 2 characters;
the Maximum Message Length (MAX) is set to 60 characters;
and the Default setting (DFT) has no value.
Trigger Commands
You can activate and deactivate the scanner with serial trigger commands. First, the scanner must be put in Manual Trigger
Mode by scanning a Manual Trigger Mode bar code (
), or by sending a serial menu command for triggering (
Once the scanner is in serial trigger mode, the trigger is activated and deactivated by sending the following commands:
Activate:
SYN T CR
Deactivate:
SYN U CR
The scanner scans until a bar code has been read, until the deactivate command is sent, or until the serial time-out has been
reached (see "Read Time-Out" on page 4-7 for a description, and the serial command on
Resetting the Custom Defaults
If you want the custom default settings restored to your scanner, scan the
Activate Custom Defaults
bar code below. This
resets the scanner to the custom default settings. If there are no custom defaults, it will reset the scanner to the factory default
settings. Any settings that have not been specified through the custom defaults will be defaulted to the factory default settings.
Note: If using a cordless system, scanning this bar code also causes both the scanner and the base or Access Point to perform
a reset and become unlinked. The scanner must be placed in its base to re-establish the link. If using an Access Point,
the linking bar code must be scanned. See
beginning on page 3-1 for additional information.
The charts on the following pages list the factory default settings for each of the commands (indicated by an asterisk (*) on the
programming pages).
Activate Custom Defaults
Содержание Granit 1911i
Страница 1: ...Xenon 1900 1910 Xenon 1902 1912 Granit 1910i 1911i Area Imaging Scanner User s Guide ...
Страница 15: ...CCB01 010BT Base Part Number Serial Number and Revision Information location Compliance Label locations ...
Страница 17: ...CCB02 100BT Base Compliance Label locations ...
Страница 18: ......
Страница 28: ...x ...
Страница 40: ...1 12 ...
Страница 90: ...3 28 ...
Страница 114: ...4 24 Vertical Bottom to Top Upside Down Vertical Top to Bottom ...
Страница 120: ...5 6 ...
Страница 184: ...7 50 ...
Страница 200: ...9 2 Denmark 8 9 6 Norway 8 9 6 Spain 6 Country Codes ...
Страница 202: ...9 4 ...
Страница 248: ...13 6 ...
Страница 263: ...Programming Chart 0 1 2 3 4 5 6 7 8 9 ...
Страница 264: ......
Страница 266: ...Honeywell Scanning Mobility 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com Xenon UG Rev H 6 13 ...