6 - 12
Data Formatter
When Data Formatter is turned Off, the bar code data is output to the host as read, including prefixes and suffixes.
You may wish to require the data to conform to a data format you have created and saved. The following settings can be applied
to your data format:
Data Formatter On, Not Required, Keep Prefix/Suffix
Scanned data is modified according to your data format, and prefixes and suffixes are transmitted.
Data Formatter On, Not Required, Drop Prefix/Suffix
Scanned data is modified according to your data format. If a data format is found for a particular symbol, those prefixes and
suffixes are not transmitted. If a data format is
not found for that symbol, the prefixes and suffixes are transmitted.
Data Format Required, Keep Prefix/Suffix
Scanned data is modified according to your data format, and prefixes and suffixes are transmitted. Any data that does not
match your data format requirements generates an error tone and the data in that bar code is not transmitted. If you wish
to process this type of bar code without generating an error tone, see
Data Format Non-Match Error Tone
Data Format Required, Drop Prefix/Suffix
Scanned data is modified according to your data format. If a data format is found for a particular symbol, those prefixes and
suffixes are not transmitted. Any data that does not match your data format requirements generates an error tone. If you
wish to process this type of bar code without generating an error tone, see
Data Format Non-Match Error Tone
Choose one of the following options.
Default = Data Formatter On, Not Required, Keep Prefix/Suffix.
Data Formatter Off
* Data Formatter On,
Not Required,
Keep Prefix/Suffix
Data Formatter On,
Not Required,
Drop Prefix/Suffix
Data Format Required,
Keep Prefix/Suffix
Data Format Required,
Drop Prefix/Suffix
Содержание Granit 1911i
Страница 1: ...Xenon 1900 1910 Xenon 1902 1912 Granit 1910i 1911i Area Imaging Scanner User s Guide ...
Страница 15: ...CCB01 010BT Base Part Number Serial Number and Revision Information location Compliance Label locations ...
Страница 17: ...CCB02 100BT Base Compliance Label locations ...
Страница 18: ......
Страница 28: ...x ...
Страница 40: ...1 12 ...
Страница 90: ...3 28 ...
Страница 114: ...4 24 Vertical Bottom to Top Upside Down Vertical Top to Bottom ...
Страница 120: ...5 6 ...
Страница 184: ...7 50 ...
Страница 200: ...9 2 Denmark 8 9 6 Norway 8 9 6 Spain 6 Country Codes ...
Страница 202: ...9 4 ...
Страница 248: ...13 6 ...
Страница 263: ...Programming Chart 0 1 2 3 4 5 6 7 8 9 ...
Страница 264: ......
Страница 266: ...Honeywell Scanning Mobility 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com Xenon UG Rev H 6 13 ...