4 - 7
Serial Trigger Mode
You can activate the scanner either by pressing the trigger, or using a serial trigger command (see
11-3). When in serial mode, the scanner scans until a bar code has been read or until the deactivate command is sent. The
scanner can also be set to turn itself off after a specified time has elapsed (see
, which follows).
Read Time-Out
Use this selection to set a time-out (in milliseconds) of the scanner’s trigger when using serial commands to trigger the
scanner. Once the scanner has timed out, you can activate the scanner either by pressing the trigger or using a serial trig-
ger command. After scanning the
Read Time-Out
bar code, set the time-out duration (from 0-300,000 milliseconds) by
scanning digits on the
inside the back cover, then scanning
Save
.
Default = 30,000 ms.
Presentation Mode
Presentation Mode uses ambient light and scanner illumination to detect bar codes. When in Presentation Mode, the LEDs
remain dim until a bar code is presented to the scanner, then the aimer turns on and the LEDs turn up to read the code. If the
light level in the room is not high enough, Presentation Mode may not work properly
Note: If you are using a cordless charge base in Presentation Mode, the battery will not charge unless the power supply is
plugged into the base’s auxiliary power port.
Scan the following bar code to program your scanner for Presentation Mode.
LED Illumination - Presentation Mode
If you wish to set the illumination LED brightness, scan one of the bar codes below. This sets the LED illumination for the
scanner when it is in Presentation Mode. (If the scanner is triggered manually, the LED illumination will switch to the setting
for a manual trigger. See "LED Illumination - Manual Trigger" on page 4-6.)
Default = High.
Note: The LEDs are like a flash on a camera. The lower the ambient light in the room, the brighter the LEDs need to be so
the scanner can “see” the bar codes.
Note: LED Illumination - Presentation Mode does not apply to
.
Read Time-Out
Presentation Mode
Off
Low
* High
Содержание Granit 1911i
Страница 1: ...Xenon 1900 1910 Xenon 1902 1912 Granit 1910i 1911i Area Imaging Scanner User s Guide ...
Страница 15: ...CCB01 010BT Base Part Number Serial Number and Revision Information location Compliance Label locations ...
Страница 17: ...CCB02 100BT Base Compliance Label locations ...
Страница 18: ......
Страница 28: ...x ...
Страница 40: ...1 12 ...
Страница 90: ...3 28 ...
Страница 114: ...4 24 Vertical Bottom to Top Upside Down Vertical Top to Bottom ...
Страница 120: ...5 6 ...
Страница 184: ...7 50 ...
Страница 200: ...9 2 Denmark 8 9 6 Norway 8 9 6 Spain 6 Country Codes ...
Страница 202: ...9 4 ...
Страница 248: ...13 6 ...
Страница 263: ...Programming Chart 0 1 2 3 4 5 6 7 8 9 ...
Страница 264: ......
Страница 266: ...Honeywell Scanning Mobility 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com Xenon UG Rev H 6 13 ...