background image

Relationship between Terminals and external LEDs

Technical data

S4-34600

Mimic LED Driver Card

Dimensions

160mm height x 150mm width x 30mm depth

Card weight

150g

Storage temperature

-30ºC to +70ºC

Operating temperature

-10ºC to +60ºC

Relative Humidity

Up to 95% - Tempe5ºC to +45°C (Non condensing)

LED output per

Mimic LED Driver Card

Up to 768 high efficiency LEDs can be driven by a

Mimic LED Driver Card

Each LED can be 3m cable distance away from the

Connection converter

.

Use only high efficiency

Red

,

Amber

or

Green

LEDs.

Vigilon Panel
compatibility

Fully compatible with LPC = V3.93 / V4.35 & MCC/MCB = V3.94 / V4.37.

Data and Installation

Mimic LED Driver Card

Gent by Honeywell reserves the right to revise this publication from time to time and make changes to the content hereof without
obligation to notify any person of such revisions of changes.

Hamilton Industrial Park, Waterside Road, Leicester LE5 1TN, UK

Website: www.gent.co.uk

Telephone: +44 (0) 116 246 2000

Technical support: www.gentexpert.co.uk

Fax (UK): +44 (0)116 246 2300

4

4188-951_issue 2_01/12_Part 1_Mimic LED driver

by Honeywell

Do not dispose of with your normal household waste.
Do not burn.

WEEE Directive:

At the end of their useful life, the packaging,
product and batteries should be
disposed of via a suitable recycling centre.

At the end of their useful life, the packaging,
product and batteries should be disposed of
via a suitable recycling centre and in
accordance with national or local legislation.

2 4 6

10

8

12 14 16 18 20

22

26

24

1 3

5

9

7

11 13 15 17 19 21

25

23

LED
Ref

+

-

LED
Ref

+

-

LED
Ref

+

-

LED
Ref

+

-

LED
Ref

+

-

LED
Ref

+

-

LED
Ref

+

-

LED
Ref

+

-

1

26

8

9

25

8

17

24

8

25

23

8

33

22

8

41

21

8

49

20

8

57

19

8

2

26

7

10

25

7

18

24

7

26

23

7

34

22

7

42

21

7

50

20

7

58

19

7

3

26

6

11

25

6

19

24

6

27

23

6

35

22

6

43

21

6

51

20

6

59

19

6

4

26

5

12

25

5

20

24

5

28

23

5

36

22

5

44

21

5

52

20

5

60

19

5

5

26

4

13

25

4

21

24

4

29

23

4

37

22

4

45

21

4

53

20

4

61

19

4

6

26

3

14

25

3

22

24

3

30

23

3

38

22

3

46

21

3

54

20

3

62

19

3

7

26

2

15

25

2

23

24

2

31

23

2

39

22

2

47

21

2

55

20

2

63

19

2

8

26

1

16

25

1

24

24

1

32

23

1

40

22

1

48

21

1

56

20

1

64

19

1

65

18

8

73

17

8

81

16

8

89

15

8

97

14

8

105

13

8

113

12

8

121

11

8

66

18

7

74

17

7

82

16

7

90

15

7

98

14

7

106

13

7

114

12

7

122

11

7

67

18

6

75

17

6

83

16

6

91

15

6

99

14

6

107

13

6

115

12

6

123

11

6

68

18

5

76

17

5

84

16

5

92

15

5

100

14

5

108

13

5

116

12

5

124

11

5

69

18

4

77

17

4

85

16

4

93

15

4

101

14

4

109

13

4

117

12

4

125

11

4

70

18

3

78

17

3

86

16

3

94

15

3

102

14

3

110

13

3

118

12

3

126

11

3

71

18

2

79

17

2

87

16

2

95

15

2

103

14

2

111

13

2

119

12

2

127

11

2

72

18

1

80

17

1

88

16

1

96

15

1

104

14

1

112

13

1

120

12

1

128

11

1

Terminal numbers on a

Connection converter

LED Ref 1

Connection Converter

LED Ref 34

Содержание GENT Mimic LED Driver Card

Страница 1: ...rd S4 34494 Connection Converter 26 way 300mm ribbon cable 20 way 200mm Flat flexible cable B A 01 L1 02 L2 0C LC P9 L N N P17 DANGER BT BT RS485 0V 24V WRITE PROTECT BUZZER DISABLE P8 DANGER DO NOT REMOVE L N P5 FS2 FS4 P16 P4 P2 P1 SW3 PB2 WD1 P14 P7 USB FS3 2A QB RESET Mimic Repeat Card P3 ADDRESS P2 BOARD UPSIDEDOWN ROTATE P1 P5 IN P16 P15 P14 P13 P12 P11 P4 OUT Mimic LED Driver Card 2 WARNING...

Страница 2: ...r the earth is connected to the Custom panel or not Do not use any part of building structure for earthing Mains supply The mains supply to the Custom panel must be via an unswitched 5A fused spur unit A disconnect device must be provided to disconnect both poles and must have a minimum gap of 3mm The disconnect device should be available as part of the building installation and must be easily acc...

Страница 3: ...end of the 26 way ribbon cable to the IDC header on the Mimic LED Driver card P11 and the other end to a Connection converter The Mimic LED Driver card can accommodate up to 6 26 way ribbon cable for wiring LEDs via 6 Connection converters 4188 951_issue 2_01 12_Part 1_Mimic LED driver 3 Mimic LED Driver Card Data and Installation P13 P4 OUT P5 IN Master Repeat Card P4 OUT P5 IN Mimic LED Driver C...

Страница 4: ...itable recycling centre At the end of their useful life the packaging product and batteries should be disposed of via a suitable recycling centre and in accordance with national or local legislation 2 4 6 10 8 12 14 16 18 20 22 26 24 1 3 5 9 7 11 13 15 17 19 21 25 23 LED Ref LED Ref LED Ref LED Ref LED Ref LED Ref LED Ref LED Ref 1 26 8 9 25 8 17 24 8 25 23 8 33 22 8 41 21 8 49 20 8 57 19 8 2 26 7...

Страница 5: ...tion converters associated with a Mimic LED Driver Card 4188 951_issue 2_01 12_Part 2_Mimic LED driver 1 Commissioning information Mimic LED Driver Card S4 34600 S4 34494 by Honeywell Do not alter these settings as they are pre defined in the LED Driver template file 7 P16_24_8 Shape number 7 Related to IDC Connector P16 on the Mimic LED Driver Card IDC connector P16 is ribbon cabled to Connection...

Страница 6: ... reserves the right to revise this publication from time to time and make changes to the content hereof without obligation to notify any person of such revisions of changes Hamilton Industrial Park Waterside Road Leicester LE5 1TN UK Website www gent co uk Telephone 44 0 116 246 2000 Fax UK 44 0 116 246 2300 2 4188 951_issue 2_01 12_Part 2_Mimic LED driver by Honeywell Drag and drop an LED Shape o...

Отзывы: