26
107111-11-EN FR26 GLO 503 Printed in Germany
7
7
7
8
8
Start muting
sensor (SM)
error
1 of the SM sensors was
activated during module
power up.
1 of the SM sensors was activated
during the start wait phase.
The second SM sensor has not
been activated within 10s after
the first one.
Muting modes with 4 muting
sensors: A new muting phase
has been identified with the
previous muting phase not ended.
Ensure SM sensors are de-activated during
module power up or start wait phase.
Move the SM sensors so that they are activated
within 10 s to start a new muting sequence.
All muting sensors SM, EM and the safety
devices must be de-activated before a new
muting sequence can be started.
8
End muting
sensor (EM)
error
1 of the EM sensors was activated
during module power up.
1 of the EM sensors was activated
during the start wait phase.
Muting modes with 4 muting
sensors: A new muting phase
has been identified with 1 EM
sensor not yet de-activated.
Ensure EM sensors are de-activated during
module power up or start wait phase.
All muting sensors SM, EM and the safety
devices must be de-activated before a new muting
sequence can be started.
APPLICATION AND
INSTALLATION ERRORS
Error
code
LED
RUN
1
LED
RUN
2
Muting
lamp
(48)
Error
type
Possible causes
Corrective actions
: switched off
: n-times flashing
n
: switched on