EKZ000300C
Page :
12/24
Installer instructions / Manuel installateur - Domonial CMI 800++ 11/2005
6 -
SPECIFICATIONS
6-1 Functional
•
4-area surveillance (Total, Part, Annex and 24hours)
•
Management of wireless peripherals of the Domonial 800 range (HF and M)
•
Digital transmission format : Secom3, Cesa, Surtec, contact ID
•
Other format : phone
•
Built-in and/or external audio half-duplex system
•
8 phone numbers / 6 call cycles
•
Events log for 1000(
1
) events
•
Built-in siren
•
Remote parameter feeding from PC and Domodem; locally from PDA or PC
6-2 Physical
MTBF
20 years
Dimensions
Height :
183mm
Width :
235mm / 295mm depending on cover
Max Depth :
50mm / 56mm
(3)
Temperature (CSEI - 11- 10 Standard)
Operating :
5 <-> 40°C
Storage :
-40 <-> 70°C
Relative humidity (CSEI - 11- 10 Standard)
< 85%
Weight (with battery)
1280 g (2822 lb)
6-3 Electrical
Power requirement
typique (U
t
) :
230V~ 50Hz, fused (200mA)
Battery
Type :
Fault :
4V 3,5Ah max.
appear : 3,57 V
disappear : after 20 minute charging
time
with GPRS module
Typical consumption (U
t
)
Normal :
Calling :
80 mA 100 mA
125 mA 270 mA
6-4 radio
Radio frequency
FM narrow band
868 Mhz
Number of channels
Total,
which might include
(2)
:
Sensors
Keyfobs
Keypads
Sirens indoor, outdoor
Other receivers (RS, X10, IRVideo)
(NB : 1 IRVIDEO = 1 1 receiver)
32
(
3
)
30
(3)
10
(3) (4)
4
(3)
4
(3)
12
(3)
Monitoring
Detectors and sirens
Once every 4 h
Radio jamming detection
See diagram page 10
Detection of transmission in the band for
more than 30s over a period of 60s
Note:
This product is in compliance with the applicable provisions of R&TTE. This equipment can be connected anywhere to the Pan-European
PSTN. However, as there are some differences in the PSTN from a country to another, this compliance is not an inherent absolute
guarantee of optimal performance irrespective of the connection point to the Pan-European PSTN. Should any problem arise, contact your
dealer first. The connection to the mains supply and phone line must be made in conformity with the local authority’s rules and regulation.
(
1
) Depending on product version, the log file can contain from 500 to 1000 events.
(
2
) Configurations, which have been tested
(
3
) Depending on product version, the number of sensors is limited to 20 or 30, the number of keypads to 2 or 4, the number of keyfobs to 5 or
10, the number of receivers to 5 or 12.
(
4
)
NF Grade 2 compliance : only 2 keyfobs should be recorded to the control panel
--
--
--
--
--
--
--
--
--
--
--
--
--
--