5-2 Mains and battery fault diagram
Loosing main power, detecting low battery and disconnecting the battery:
Mains loss
Battery voltage < 3,57 V
Battery discharging
230V light
Sending mains
Sending battery fault to the ARC
Switch OFF
fault to the ARC
then automatically disconnecting the battery (panel stopped)
Main power return and re-connecting the battery:
Mains return
Battery charging
(during 20mn, the battery doesn’t power the panel)
Panel starts,
Sending mains
Sending battery return
Mains Light
return to the ARC
to the ARC and switching off
And System
system fault light
Fault light
5-3 : Knowledge of the various formats
Secom 3:
Secom 3 is a DTMF Format. Used in conjunction with control panel + it features:
-
Identifier code (8 Numeric digits).
-
Numeric codes from 0 to 98.
-
Checksum verifying the received and transmitted data frame integrity.
-
Information to the ARC as to the period of time elapsed between alarm activation and surveillance arming.
-
Area surveillance status upon cyclic testing.
-
Listening duration between 1 and 240 seconds
-
Compatibility with the pictures transfer using the PIR/Camera detector IRV800M
-
Changing to Modem mode (owner) for switching to Secom-Vat protocol (remote parameter setting and maintenance)
-
Digital communicator time setting from the alarm receiver.
-
Optional automated scripts via Honeywell’s server IST, Technical Service Integrator.
This format is supported by Honeywell’s PE1500 and PE1800 alarm receivers.
Formats codes:
The following table shows the codes corresponding to each format.
Dedicated codes are programmed as default in the panel.
.
Communication format
Secom3
Surtec
Cesa
Contact ID
Client number
Numeric
(8 char.)
Numeric
(5 Char.)
4 char. Hexadecimal except
A
Alarm
0 to 98
0 to 98
0 to 99
100 - 199
Low battery (appearance)
91
91
0 to 99
302
Low battery (disappearance)
90
90
0 to 99
302
Cyclic test
0 to 98
92
0 to 99
602
Remote test
0 to 98
93
0 to 99
601
Reset
0 to 98
03
0 to 99
305
Total arming
94
94
0 to 99
400
Total disarming
95
95
0 to 99
400
Audio verification follows
606
15mn