EKZ000300C
Page :
3/24
Installer instructions / Manuel installateur - Domonial CMI 800++ 11/2005
1-2 Control panel
The control panel, depending of the programming, covers:
-
1
Total
area (or Main)
-
1
Part
area
-
1
Annex or Perimeter
area
Arming / Disarming
Arming and disarming can be controlled as follows:
Areas
Keypad
Keyfob
Remote DTMF
Code by phone
By PDA or PC software
Total ARMING
Y
Y
Y
Y
(*)
Part ARMING
Y
Y
Y
Y
(*)
Total DISARMING
Y
Y
Y
(*)
Y
(*)
Annex area ARMING
Y
Y (depends on setup)
Y
Y
(*)
Annex area DISARMING
Y
Y(depends on setup)
Y
(*)
Y
(*)
Users
The control panel allows up to 10 users (including master). The keyfobs/keypads and the codes are assigned for each user.
Each user can have a code and/ or a TAG set on each mono-directional keypad, or shared by all bidirectional keypads.
Users can be supervised so the user’s Id is stored in the events log and reported to the monitoring station.
In addition, a set of pictures can be taken on arming/disarming and sent to the monitoring station when setup.
Dedicated profiles for limited time access and clocking are also available on some versions of the product.
Alarm detection
The detectors can be programmed:
-
Delayed: with an entry/exit delay programmable from 0 to 90 seconds (for total, part or annex area).
-
Mixed: delay or instant trigger depending on which input is activated first.
-
Immediate : direct trigger
Technical devices are programmed as “24/24” and trigger independently of area arming status.
Alarm signaling
Several sounder operating modes are available:
-
Standard siren.
-
Siren activated upon intrusion or loss of PSTN.
-
Siren activated on tamper detection (24/24) or only when Total area is armed.
-
Siren activated on fire detection.
Intrusion sounding duration can be programmed from 0 to 240 seconds.
Activation of the sounder can also be postponed until after the alarm signal has been transmitted.
Fire sounding
(*)
duration is fixed to 300 seconds and can be delayed from 0 to 300 seconds
For more details, see manual for DomoPDA programming tool (EKZ000800)
*
This function is available depending on product version and country regulations
T
P
A