CT50A, CT51A, CT53A THERMOSTATS

69-0265ES

2

!

Using a pencil point, move the heat anticipator pointer 
to the number it was set to on the old thermostat. If you 
could not find the anticipator setting on the old 
thermostat, use the setting for your type of system 
shown in the table below.

NOTES: If the furnace stays on beyond the thermostat set 

temperature, move the anticipator pointer down 
by 0.1 ampere.
If the furnace shuts off before the set tempera-
ture is reached, move the anticipator pointer up 
by 0.1 ampere.
Never adjust the anticipator below 0.3 ampere.

!

Loosen screws holding thermostat to the wall and 
lift away.

!

Disconnect wires from old thermostat or subbase. If 
your thermostat has more than 2 wires, as you 
disconnect each wire, tape the end and label it with the 
letter of the terminal designation to make reconnection 
to new thermostat easier. Take care that these wires 
do not fall back into the wall opening.

!

Retain the old thermostat for reference purposes until 
your new thermostat is functioning smoothly.

WIRE AND MOUNT

NEW THERMOSTAT

For CT50A

!

Connect one of the 2 wires from the wall to each of the 
two terminals on the back of the thermostat. Tighten 
the screws.

For CT51A

!

Connect 4 wires from the wall to matching terminals on 
back of thermostat. Tighten the screws.

!

If using CT51A for ELECTRIC heat systems, you must 
install a jumper between thermostat terminals 1 and 2.

CT53A

!

Connect wires to R and W for 750 mV systems. 
Connect to R and Y for 250 or 500 mV systems. 
Tighten the screws.

!

Grasp the thermostat cover at the top and bottom with 
one hand. Pull outward on the top edge of the 
thermostat cover until it snaps free of the thermostat 
base.

!

Carefully remove and discard the red plastic pin 
located above the mercury switch. This pin protects 
this switch during shipment.

!

Fasten thermostat to the wall with one of the screws 
supplied, using the top mounting hole.

!

Place your level across the top of the thermostat and 
level it. Start the second screw, supplied, in the center 
of the bottom mounting hole.

!

Recheck for level positioning, then firmly tighten both 
mounting screws.

Table 1. Heat Anticipator Settings.

Your heating system

Heat anticipator setting

Steam

1.2

Hot water heat

0.8

High-efficiency warm air

0.8

Standard warm air

0.4

Electric heat

0.3

M3775

TERMINAL

SCREWS

(CT51A SHOWN)

M11902

Содержание CT50A, CT51A, CT53A

Страница 1: ... from the bottom If it resists check for a screw that locks the cover on MERCURY NOTICE If this product is replacing a control that contains mercury in a sealed tube do not place the old control in the trash Contact your local waste management authority for instructions regarding recycling and proper disposal For CT50A CT51A Installation Before removing the old thermostat from the wall look at it ...

Страница 2: ...50A Connect one of the 2 wires from the wall to each of the two terminals on the back of the thermostat Tighten the screws For CT51A Connect 4 wires from the wall to matching terminals on back of thermostat Tighten the screws If using CT51A for ELECTRIC heat systems you must install a jumper between thermostat terminals 1 and 2 CT53A Connect wires to R and W for 750 mV systems Connect to R and Y f...

Страница 3: ...ion for at least one cycle on both heating and cooling To observe Place the system switch at HEAT position and fan switch at AUTO Move the temperature sensing lever to 10 F 6 C above room temperature The furnace should turn on A short warm up period may be required before the system fan turns on Place system switch at COOL position and move temperature sensing lever 10 F 6 C below room temperature...

Страница 4: ...on costs This warranty shall not apply if it is shown by Honeywell that the defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer Honeywell s sole responsibility shall be to repair or replace the product within the terms stated above HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL D...

Страница 5: ...te inferior Si se resiste busque el tornillo que traba la tapa ADVERTENCIA SOBRE EL MERCURIO Si este producto está reemplazando un control que contiene mercurio en un tubo sellado no tire el control viejo a la basura Comuníquese con su autoridad local de gestión de desperdicios para obtener instrucciones respecto del reciclado y la forma de disposición adecuada Instalación de los modelos CT50A CT5...

Страница 6: ...posterior del termostato Ajuste los tornillos Para el modelo CT51A Conecte los 4 cables que vienen de la pared a las terminales correspondientes que se encuentran en la parte posterior del termostato Ajuste los tornillos Si utiliza el modelo CT51A para sistemas de calefacción ELÉCTRICA debe instalar un puente entre las terminales 1 y 2 del termostato Para el modelo CT53A Conecte los cables a R y W...

Страница 7: ...as de calefacción y de refrigeración Siga los siguientes pasos Coloque el interruptor del sistema en la posición CALEFACCION y el interruptor del ventilador en AUTO Mueva la palanca de la temperatura a 10 ºF 6 ºC sobre temperatura ambiente Debería encenderse el calentador Puede ser necesario esperar un período corto de calentamiento antes de encender el ventilador del sistema Coloque el interrupto...

Страница 8: ...tía no se aplicará si Honeywell demuestra que el defecto o mal funcionamiento estaba causado por daños ocurridos mientras el producto estaba en posesión de un consumidor La única responsabilidad de Honeywell será reparar o reemplazar el producto dentro de los plazos establecidos anteriormente HONEYWELL NO RESPONDERA POR LA PERDIDA O DANO DE NINGUN TIPO INCLUIDO EL DANO INCIDENTAL O INDIRECTO QUE D...

Отзывы: