Honeywell CONTROLBUS QS7800B Скачать руководство пользователя страница 2

QS7800B NETWORK INTERFACE CONTROLBUS™ MODULE FOR MULTI-DROPPING 7800 SERIES RELAY MODULES

65-0227—2

2

ORDERING INFORMATION

When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the 
TRADELINE® Catalog or price sheets for complete ordering number.

If you have additional questions, need further information, or would like to comment on our products or services, please write or 
phone:

1.

Your local Home and Building Control Sales Office (check white pages of your phone directory).

2.

Home and Building Control Customer Relations
Honeywell, 1885 Douglas Drive North
Minneapolis, Minnesota 55422-4386

In Canada—Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Scarborough, Ontario M1V 4Z9.
International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, 
Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A.

SPECIFICATIONS

Models: 

QS7800B1000 Network Interface ControlBus™ 

Module for use with the S7810B Multi-Drop Switch Module 
and Q7700A1014 and Q7700B1004 Network Interface 
Unit. 

Electrical Ratings:

ControlBus™ Communication.
Current Draw: 75 mA.

Electrical Connectors: 

ControlBus™ Three-Prong Electrical 

Connector.

Environmental Ratings:

Ambient Temperature:

Operating: 32°F to 130°F (0°C to 54°C).
Storage: -30°F to +150°F (-34°C to +66°C).

Humidity: Operating 85 percent relative humidity, continuous, 

noncondensing.

Vibration: Continuous 0.5G.
Enclosure: NEMA 1.

Dimensions:  

See Fig. 1.

Weight: 

 8 oz (unpacked).

Accessories:

221237/1698 Cover Assembly, Q7700 Network Interface Unit.
221240/1698 Cover Assembly, Q7700 Electrical Enclosure, 

Network Interface Unit.

202433 Slot Inserts, ControlBus™ Slots Base Unit.
200603 ControlBus™ Electrical Connector.

Approvals:

Underwriters Laboratories Inc: File No. MP268, Guide No. 

MCCZ2.

Canadian Standards Association: LR80141 .
Federal Communications Commission: Part 15, Class A Emis-

sions, Part 68.

FCC: Registration Number HS92SJ-10735-DT-E.
Canadian Department of Communication: CS-03, Certification 

Number 573-3459A.

IMPORTANT

This equipment complies with the requirements in 
part 15 of FCC rules for a Class A computing device. 
Operation of this equipment in a residential area can 
cause unacceptable interference with radio and 
television reception that requires the operator to take 
whatever steps are necessary to correct 
interference.

Warning:

 This equipment generates, uses, and can radiate 

radio frequency energy, and if not installed and used in 
accordance with the Instructions Manual, may cause 
interference with radio communication. It has been tested and 
found to comply with the limits for a Class A computing device 
pursuant to Subpart J of Part 15 of FCC Rules, which are 
designed to provide reasonable protection against such 
interference when operated in a commercial environment. 
Operation of this equipment in a residential area is likely to 
cause interference,  in which case, user at their own expense 
will be required to take whatever measures may be required 
to correct the interference. Any unauthorized modification of 
this equipment may result in the revocation of the owner’s 
authority to continue its operation.

Canadian EMI:

 This digital apparatus does not exceed the 

Class A limits for radio noise emission from digital apparatus 
set out in the Radio Interference Regulations of the Canadian 
Department of Communications.

Le présent appareil numérique n’émet pas de bruits 
radioélectriques dépassant les limites applicables aux 
appareils numériques de la Classe A prescrites dans le 
Règlement sur le brouillage radioeléctrique édicté par le 
ministère des Communications du Canada.

INSTALLATION

When Installing this Product...

1.

Read these instructions carefully. Failure to follow them 
could damage the product or cause a hazardous 
condition. 

2.

Check the ratings given in the instructions and on the 
product to make sure the product is suitable for your 
application.

Содержание CONTROLBUS QS7800B

Страница 1: ...imum of 222 multi dropped subnetworks per Q7700 Network Interface Unit Up to 31 multi dropped 7800 SERIES subnetworks per QS7800B ControlBus Module without using an RS 485 repeater Up to 61 multi dropped 7800 SERIES subnetworks per QS7800B ControlBus Module using an RS 485 repeater Local and remote annunciation of 7800 SERIES Relay Module faults Personal computer user interface Microsoft Windows b...

Страница 2: ...ederal Communications Commission Part 15 Class A Emis sions Part 68 FCC Registration Number HS92SJ 10735 DT E Canadian Department of Communication CS 03 Certification Number 573 3459A IMPORTANT This equipment complies with the requirements in part 15 of FCC rules for a Class A computing device Operation of this equipment in a residential area can cause unacceptable interference with radio and tele...

Страница 3: ...rface Unit Be sure to allow clearances for servicing installing and removing the wiring compartment cover Network Interface Unit cover electrical connectors and ControlBus Modules a Allow for an additional 2 1 2 inches 64 mm minimum below the Network Interface Unit for electrical connector installation b Allow for an additional 1 1 2 inches 38 mm minimum on each side for electrical housing cover i...

Страница 4: ... 9 pin RS 232 connector of the Network Interface Unit see Fig 4 9 Connect the serial port of the personal computer to the 25 pin RS 232C port on the Network Interface Unit for local personal computer application see Fig 3 10 Do not exceed 600 mA current draw six card maximum total capacity of the plug in cards Refer to the ControlBus Module device label and this specification for individual loads ...

Страница 5: ...SHIELDED CABLE BELDEN 8723 OR EQUIVALENT IS RECOMMENDED CABLE SHIELD MUST BE GROUNDED AT EACH END MULTI DROP COMMUNICATION BUS TERMINATION RESISTORS A WITHOUT RS 485 REPEATER MODULES AT THE CLOSEST AND FARTHEST END OF THE DAISY CHAIN REQUIRE TERMINATION RESISTORS INSTALL A 120 OHM 1 4 WATT RESISTOR BETWEEN TERMINALS a AND b of the QS7800B CONTROLBUS MODULE INSTALL A 120 OHM 1 4 WATT RESISTOR BETWE...

Страница 6: ...ule is required in each subnetwork See Fig 6 for wiring information Subnetworks can be spread evenly balanced across the NIU slots This will help to speed communications It is recommended that the multi drop network be built starting with slot number 1 of the NIU according to the guidelines above Record the serial number and physical location of each S7810B Multi Drop Switch This data will be usef...

Страница 7: ...7 65 0227 2 ...

Страница 8: ...nal Honeywell Europe S A Honeywell Latin American Honeywell Honeywell Limited Honeywell Limitée Control Products 3 Avenue du Bourget Region 1985 Douglas Drive North 35 Dynamic Drive Honeywell Building 1140 Brussels 480 Sawgrass Corporate Parkway Golden Valley MN 55422 Scarborough Ontario 17 Changi Business Park Central 1 Belgium Suite 200 M1V 4Z9 Singapore 486073 Sunrise FL 33325 ...