BCU 460, BCU 465 · Edition 11.19
16
Application
1 .1 .9 ON/OFF rotary impulse
control
For processes which require a turn-
down of more than 10:1 and/or
those which require heavy circula-
tion of the furnace atmosphere to
ensure a uniform temperature, e.g.
heat treatment furnaces operating
at low and medium temperatures in
the metallurgical industry.
With ON/OFF cyclic control, the
capacity supplied to the process is
controlled by means of a variable
ratio of the operating time to the
pause time. In this type of control,
the burner output pulse frequency
always maintains full momentum
and results in maximum convection
in the furnace chamber, even with
regulated heating.
▼
M
PZL
PZH
PZ
PZL
PDZ
TE
M
BCU 460/
LM..F3
BCU 460/
LM..F3
FCU 500..F0
µC
P
DG
DG
DG
VAS
VAS
VAS
VCG
VCG
VR..L
VR..L
DG
DG
DG
min
DG
max
49
15
13
14
50
45
47 48
58
>750°
p
u
/2
ϑ
1
46
2
3
DL
min
DL
Purge
STM