Tariff Block Counter Matrix
Matrix for storing Block Counters for Block Pricing
Tariff TOU Register Matrix
Matrix for storing Tariff Registers for Time-of-use Pricing.
Tariff TOU Block Register Matrix
Matrix for storing Tariff Registers for Time-of-use with Block Pricing.
Time Debt Re
gisters [1 … 2]
Two registers recording independent debts to be recovered over time when
operating Time-based Debt Recovery in Prepayment Mode.
Constant Data
SMETS2 reference
Description
AS302P Identifier
A globally unique identifier used to identify an individual AS302P based on the
EUI-64 Institute of Electrical and Electronic Engineers standard.
Manufacturer Identifier
An identifier used to identify the manufacturer of the meter
Model Type
An Identifier used to identify the model of the meter
Meter Variant
An Identifier used to identify if the meter is Single, Twin element or Polyphase
Randomised Offset Number
Randomly Generated 0 or 1
Internal Data
SMETS2 reference
Describes Data that Remains Constant and is not Available Outside the
Meter
Installation Credentials
Credentials Unique to the Meter
Configuration Data
SMETS2 reference
Description
Alerts Configuration settings
Generate/Send an Alert
Auxiliary Load Control Switch Calendar
Set of Switching Rules for up to 5 Auxiliary Load Control switches
Auxiliary Load Control Switch Description
Description of Control of Each Auxiliary Load Control Switch
Average RMS Over Voltage
The average RMS voltage above which an over voltage condition is reported
Average RMS Under Voltage Threshold
The average RMS voltage below which an under voltage condition is reported.
Average RMS Voltage Measurement
Period
The length of time in seconds over which the RMS voltage is averaged.
Billing Calendar
A calendar defining billing dates for the storage of billing related information
Contact Details
The name and contact telephone number of the Supplier.
Currency Units
The Currency Units currently used by the meter (Pound/Euros)
Customer Identification Number
A number issued to meter for display on the User Interface.
Debt Recovery per Payment
The percentage of a payment to be recovered against debt
Debt Recovery Rates [1 … 2]
Two debt recovery rates in Currency Units per unit time
Debt Recovery Rate Cap
The maximum amount in Currency Units per unit time that can be recovered
Device Log
The Security Credentials for each of the Type 1 Devices and Type 2 Devices
Disablement Threshold
The threshold in Currency Units for controlling when to Disable the Supply
Emergency Credit Limit
The amount of Emergency Credit in Currency Units to be made available to a
Consumer
Emergency Credit Threshold
The threshold in Currency Units below which Emergency Credit Balance may be
activated
Meter Security Credentials
The Security Credentials for Meter
Load Limit Period
Length of time in which Active Power Import continuously exceeds the Load Limit
Power threshold before Load Limit Event Occurs
Load Limit Power Threshold
The Active Power threshold in kW above which the measurement of a Load Limit
Period is commenced.
Load Limit Restoration Period
The length of time in seconds after the Supply has been Armed following a Load
Limiting Event before the Supply is Enabled by AS302P.
Configuration Data (Contd)
Load Limit Supply State
Control the state of the Supply in the case of a load limiting occurring, being
Disabled or unchanged.