![Honeywell AS302P Скачать руководство пользователя страница 37](http://html.mh-extra.com/html/honeywell/as302p/as302p_operating-instructions-manual_151788037.webp)
Operating & Maintenance Instructions
33
__________________________________________________________________________
©
Honeywell - M450 001 1D - 23.05.2019
19.7. Display Indicators
Meter Error Alarm
Energy Direction Indicators (+A, -A, +R, -R)
Load Control Indicator (Icon flashes when over limit)
Auxiliary relay, indicates open or closed (smaller icon)
Main contactor, indicates open or closed (larger icon)
HAN
– Blinking fast – Communicating (future release)
Fixed
– On a comms network (future release)
WAN Signal strength indicator
19.8. Display Function Triggers
The following triggers override the display when the meter is in Scroll Mode. They will remain on the display until a
Pushbutton is pressed.
Trigger
Action
Failed manual entry of UTRN
Display reason for failure until a button is pressed
Emergency Credit becomes Available
Display offer of Emergency Credit until accepted/rejected or
Emergency Credit becomes unavailable
Low Credit Warning Threshold
Reached
Sound Audible Alarm (optional). Override display with Low Credit
Warning message (optional), until Available Credit exceeds Low Credit
Warning Threshold or button is pressed.
Load Limit
Indication that the Load Limit Threshold has been exceeded for a
configurable length of time.
19.9. Privacy (Customer) PIN
Privacy (Customer) PIN Protection enables access to certain displays / functions via the display/pushbuttons*. Access to
these PIN protected displays can be gained by:
•
Input of a number, 4 digits, that matches the Privacy PIN
To enter the code:
•
Use the Top Button to increment the first digit (The digit to be entered will be flashing)
•
Long Press the Top Pushbutton to move to the next digit
•
Repeat above 2 steps for all 4 digits
•
On the 4
th
digit, hold the Two Pushbutton together for a Long Press to indicate the entry is complete
The User can:
•
Set a new value for the Privacy PIN (via the Pushbuttons)
-
This will Change the PIN, if it was previously Enabled
-
This will Enable the PIN, if previously Disabled
•
Disable the PIN
Command from the WAN can be sent to:
•
Disable Privacy PIN Protection
An event will be created in the Event Log (with appropriate code) when the PIN is disabled or changed via the
Pushbuttons.
Honeywell suggests that the Utility providing the meter includes in its User Guide advice on: selection, secure handling or
entry of the user PIN.
*Note
– 1 Minute Timeout
Содержание AS302P
Страница 1: ...AS302P SINGLE PHASE SMART METER OPERATING INSTRUCTIONS M450 001 1D 23RD MAY 2019 ...
Страница 4: ......