Operating & Maintenance Instructions
73
__________________________________________________________________________
©
Honeywell - M450 001 1D - 23.05.2019
Event Log (Contd)
Event / Alert Code Meaning
Event /
Alert Code
Mandated /
Non-mandated
Alert
WAN
(Alert Type)
Alert
HAN
Error Watchdog
0x81B3
Non-mandated
Y (1)
N
Meter Cover Closed
0x81B9
Non-mandated
Y (1)
N
Request Tunnel Command Rejected
0x81BA
Non-mandated
Y (1)
N
Strong Magnetic Field Removed
0x81BC
Non-mandated
Y (1)
N
Supply Connect Failure (Valve or Load Switch)
0x81BD
Non-mandated
Y (1)
N
Supply Disabled Then Locked - Supply Tamper
State Cause
0x81BE
Non-mandated
Y (1)
N
Supply Disconnect Failure (Valve or Load Switch)
0x81C0
Non-mandated
Y (1)
N
Terminal Cover Closed
0x81C1
Non-mandated
Y (1)
N
UTRN Manual Entry Suspended
0x81C4
Non-mandated
Y (1)
Y
UTRN rejected as locked out
0x81C5
Non-mandated
Y (1)
N
Power Event Log
Event / Alert Code Meaning
Event / Alert
Code
Mandated /
Non-mandated
Alert
WAN
(Alert Type)
Alert
HAN
Average RMS Voltage above Average RMS
Over Voltage Threshold (current value above
threshold; previous value below threshold)
0x8002
Mandated
Y (1)
N
Average RMS Voltage below Average RMS
Under Voltage Threshold (current value below
threshold; previous value above threshold)
0x8006
Mandated
Y (1)
N
RMS Voltage above Extreme Over Voltage
Threshold (voltage rises above for longer than
the configurable period)
0x8020
Mandated
Y (1)
N
RMS Voltage above Voltage Swell Threshold
(voltage rises above for longer than the
configurable period)
0x8024
Mandated
Y (1)
N
RMS Voltage below Extreme Under Voltage
Threshold (voltage falls below for longer than the
configurable period)
0x8028
Mandated
Y (1)
N
RMS Voltage below Voltage Sag Threshold
(voltage falls below for longer than the
configurable period)
0x802C
Mandated
Y (1)
N
Supply Outage Restored
0x8F35
Mandated
Y (2)
N
Supply Outage Restored - Outage >= 3 minutes
0x8F36
Mandated
Y (2)
N
Supply Outage Restored on Phase 1
0x8F37
Mandated
Y (2)
N
Supply interrupted
0x8157
Mandated
N
N
Average RMS Voltage below Average RMS
Over Voltage Threshold (current value below
threshold; previous value above threshold)
0x8085
Mandated
Y (1)
N
Average RMS Voltage above Average RMS
Under Voltage Threshold (current value above
threshold; previous value below threshold)
0x8089
Mandated
Y (1)
N
RMS Voltage above Extreme Over Voltage
Threshold (voltage returns below for longer than
the configurable period)
0x808D
Mandated
Y (1)
N
RMS Voltage above Voltage Swell Threshold
(voltage returns below for longer than the
configurable period)
0x8091
Mandated
Y (1)
N
RMS Voltage below Extreme Under Voltage
Threshold (voltage returns above for longer than
the configurable period)
0x8095
Mandated
Y (1)
N
RMS Voltage below Voltage Sag Threshold
(voltage returns above for longer than the
configurable period)
0x8099
Mandated
Y (1)
N