IGSMV
/
IGSMVCN Installation and Setup Guide
5-4
The second line of the display shows loaded battery voltage.
An asterisk (
*
) next to the voltage indicates that this is below
the accepted level.
Press the [Space] key to go to the next field.
Press the backspace [BS] key to go to the previous field.
Battery Charger
OK
Battery Charger Status Display
The status of the battery charger circuit of the
IGSMV can be viewed on the 7720P. The status is either OK
or NOT OK.
Press the [Space] key to go to the next field.
Press the backspace [BS] key to go to the previous field.
Line Voltage
xx.xxV
Line Voltage Display
The line voltage of the IGSMV can be viewed on the 7720P.
An asterisk (
*
) next to the voltage indicates that this is below
the accepted level.
Press the [Space] key to go back to the System Status
Display.
Press the backspace [BS] key to go to the previous field.
[T]
Test Msg Sent
Test Alarm
Sends a Test alarm to AlarmNet. Functional for a
registered
IGSMV only. If the device is not registered, a message is
displayed indicating that the command cannot be executed.
[X]
Reset CPU Y/N
Reset the IGSMV.
Pressing [N] returns to diagnostic mode (blank screen = enter
next command or escape).
Pressing [Y] resets the module (blank screen = reset
complete).
[
]
(UP
arrow)
Registering …
Registration
Registers a programmed IGSMV with AlarmNet
.
[
]
(DN
arrow)
Enter PIN#
Registration with PIN for Replacement Module
Registers a replacement IGSMV with AlarmNet, once pro-
grammed, using the existing PIN #.
Force Upload of Configuration File to Server
Pressing [Y] will force the device to upload its entire configu-
ration file to the server.
Pressing [N] cancels the operation.
NOTE:
If the internet is not available, and the IGSMV
module is not initialized when you enter this command, the
following screen will be displayed:
Cannot Upload
Try Later! _
[0]
Force Server Update?
Y/N
Wait for the RSSI LEDs to light, indicating the IGSMV
module has completed its initialization, and try again.
[ENT
ER]
Strt Prog Mode?
Y/N_
Enter Program Mode
Press [Y] to enter program mode; otherwise, press [N].
Содержание AlarmNet IGSMV
Страница 2: ......
Страница 20: ...IGSMV IGSMVCN Installation and Setup Guide 2 10 ...
Страница 46: ...IGSMV IGSMVCN Installation and Setup Guide 4 4 ...
Страница 54: ...IGSMV IGSMVCN Installation and Setup Guide A 2 ...
Страница 56: ...IGSMV IGSMVCN Installation and Setup Guide B 2 ...
Страница 58: ...IGSMV IGSMVCN Installation and Setup Guide C 2 ...
Страница 60: ...IGSMV IGSMVCN Installation and Setup Guide D 2 ...
Страница 61: ...NOTES ...
Страница 62: ...NOTES ...