![Honeywell Ademco VISTA-50P Скачать руководство пользователя страница 74](http://html.mh-extra.com/html/honeywell/ademco-vista-50p/ademco-vista-50p_installation-and-setup-manual_153286074.webp)
VISTA-50P/VISTA-50PUL Installation and Setup Guide
6-10
PROMPT
EXPLANATION
01 Time Window ?
00:00 00:00 01
Enter the time window number (
01-20
) for which this timed event is to occur. As the number is keyed in, the
actual time that has been stored for the time window number is displayed.
Press [
✳
] to accept entry.
01 Active time ?
0
Enter the activation time from
1-10
(listed below). As the number is keyed in, the activation time is
displayed. The choices are:
1:
Trigger at the start of the window.
2:
Trigger at the end of the window.
3:
Take effect only for the duration of the window.
4:
Trigger at both the start and the end of the window. Example: coffee break buzzer.
Press [
✳
] to accept entry.
Days ? MTWTFSSH
Hit 0-8 x x
The system then asks for which days the event is to be activated.
Press
0
to toggle all days on or off; or press keys
1-8
to toggle the letter “x” under the day on or off (Monday
= 1, Holiday = H = 8).
When all entries have been made, the “TIMED EVENT #?” prompt is displayed again.
Repeat the procedure for each timed event for the installation.
Quit ?
1 = YES 0 = NO
0
Enter
0
at the “Quit ?” prompt to return to the main menu choices and continue programming. Enter
1
to quit
Scheduling Menu Mode.
Limitation of Access Schedules
Limitation of Access is a means by which a user’s access
code is limited to working during a certain period of
time. The system provides 8 Access Schedules, each of
which consists of two time windows for each day of the
week and two time windows for holidays (typically, one
for an opening time window and the second for a closing
time window). A user, required to follow a schedule,
would be assigned to an access group of the same
number (e.g., schedule 1= group 1).
The user’s access code is assigned to a group when that
user is added to the system. If no limitations apply,
enter
0
.
Limitation of Access Schedule Worksheet
Enter the appropriate time window numbers for each access schedule.
Acc
Mon
Tues
Wed
Thurs
Fri
Sat
Sun
Hol
Sch
W1
W2
W1
W2
W1
W2
W1
W2
W1
W2
W1
W2
W1
W2
W1
W2
1
2
3…8
NOTE:
The holidays used for the access groups are the same as those defined in the holiday schedule.
Limitation of Access Schedules Programming
To program access schedules enter Scheduling Menu Mode
Installer Code + # 80
. After entering Scheduling Menu
Mode, press
[0]
until the “Access Sched. ?” prompt appears.
PROMPT
EXPLANATION
Access Sched. ?
1 = YES 0 = NO
0
Enter
1
to program access schedules.
WWW.DIYALARMFORUM.COM
Содержание Ademco VISTA-50P
Страница 2: ...ii WWW DIYALARMFORUM COM ...
Страница 12: ...VISTA 50P VISTA 50PUL Installation and Setup Guide 2 4 WWW DIYALARMFORUM COM ...
Страница 40: ...VISTA 50P VISTA 50PUL Installation and Setup Guide 3 28 WWW DIYALARMFORUM COM ...
Страница 48: ...VISTA 50P VISTA 50PUL Installation and Setup Guide 4 8 WWW DIYALARMFORUM COM ...
Страница 64: ...VISTA 50P VISTA 50PUL Installation and Setup Guide 5 16 WWW DIYALARMFORUM COM ...
Страница 78: ...VISTA 50P VISTA 50PUL Installation and Setup Guide 6 14 WWW DIYALARMFORUM COM ...
Страница 82: ...VISTA 50P VISTA 50PUL Installation and Setup Guide 7 4 WWW DIYALARMFORUM COM ...
Страница 84: ...VISTA 50P VISTA 50PUL Installation and Setup Guide 8 2 WWW DIYALARMFORUM COM ...
Страница 98: ...VISTA 50P VISTA 50PUL Installation and Setup Guide B 2 WWW DIYALARMFORUM COM ...
Страница 100: ...VISTA 50P VISTA 50PUL Installation and Setup Guide C 2 WWW DIYALARMFORUM COM ...
Страница 102: ...VISTA 50P VISTA 50PUL Installation and Setup Guide D 2 WWW DIYALARMFORUM COM ...
Страница 110: ...WWW DIYALARMFORUM COM ...
Страница 111: ...WWW DIYALARMFORUM COM ...