Section 5 – Data Field Descriptions
5-9
FIELD
TITLE and DATA ENTRIES
EXPLANATION
1*08
Response Types for Zones 81–87
Skip this field. Use #93 Menu Mode, Zone Programming to program the
response types. Refer to the
Programming Guide
for details.
1*09
Response Types for Zones 88–91
Skip this field. Use #93 Menu Mode, Zone Programming to program the
response types. Refer to the
Programming Guide
for details.
1*17
Lobby Partition
0
= none
1-8
= partition number
Select the Common Lobby Partition.
1*18
Affects Lobby (partition-specific)
0
= disable
1
= enable
If enabled, causes lobby partition to disarm when this partition disarms.
NOTE:
This partition must be armed before lobby can be armed.
1*19
Arms Lobby (partition-specific)
0
= disable
1
= enable
If enabled, arming this partition causes the system to attempt to arm the
lobby partition automatically. To enable this field, field 1*18 must also be
enabled (partition-specific).
NOTES:
The lobby cannot be armed unless all partitions programmed for “affect”
(field 1*18) is already armed.
If his field is enabled, Field 1*18 for this partition must also be enabled.
Exit Error Logic Enable
0
= disable
1
= enable
Exit Error Logic functions as follows: the system at the end of the exit
delay, if a door is left open or an interior zone is faulted, starts the entry
delay period, and sounds the bell(s), siren(s), and keypad sounders for the
duration of entry delay. This gives the user time to re-enter the premises
and disarm the system before exit error occurs.
If the user does not re-enter the premises and disarm the system, the
system bypasses the faulted entry/exit and/or interior zone(s). The rest of
the system is armed. In addition, the following dialer reports are sent to
the central station if programmed:
Exit Error by User (not sent when is using ADEMCO High Speed format)
Entry/Exit or Interior Alarm with the zone number
Bypass reports
UL
Exit Error Logic is not suitable for use in a UL installation.
1*20
Exit Delay Reset
0
= disable
1
= enable
If enabled, when the panel is armed, the normal exit delay begins. After
the user exits, closes the door and then re-enters the premises, the exit
delay time is reset to the programmed value.
NOTES:
Exit Delay Reset is designed to allow an operator to re-enter the premises
to retrieve a forgotten item without triggering an alarm. This feature may
only be activated once after arming.
UL
Exit Delay Reset is not suitable for use in a UL installation.
1*21
WWW.DIYALARMFORUM.COM
Содержание Ademco VISTA-50P
Страница 2: ...ii WWW DIYALARMFORUM COM ...
Страница 12: ...VISTA 50P VISTA 50PUL Installation and Setup Guide 2 4 WWW DIYALARMFORUM COM ...
Страница 40: ...VISTA 50P VISTA 50PUL Installation and Setup Guide 3 28 WWW DIYALARMFORUM COM ...
Страница 48: ...VISTA 50P VISTA 50PUL Installation and Setup Guide 4 8 WWW DIYALARMFORUM COM ...
Страница 64: ...VISTA 50P VISTA 50PUL Installation and Setup Guide 5 16 WWW DIYALARMFORUM COM ...
Страница 78: ...VISTA 50P VISTA 50PUL Installation and Setup Guide 6 14 WWW DIYALARMFORUM COM ...
Страница 82: ...VISTA 50P VISTA 50PUL Installation and Setup Guide 7 4 WWW DIYALARMFORUM COM ...
Страница 84: ...VISTA 50P VISTA 50PUL Installation and Setup Guide 8 2 WWW DIYALARMFORUM COM ...
Страница 98: ...VISTA 50P VISTA 50PUL Installation and Setup Guide B 2 WWW DIYALARMFORUM COM ...
Страница 100: ...VISTA 50P VISTA 50PUL Installation and Setup Guide C 2 WWW DIYALARMFORUM COM ...
Страница 102: ...VISTA 50P VISTA 50PUL Installation and Setup Guide D 2 WWW DIYALARMFORUM COM ...
Страница 110: ...WWW DIYALARMFORUM COM ...
Страница 111: ...WWW DIYALARMFORUM COM ...