– 37 –
PROMPT
EXPLANATION
02 RELAY TYPE
V-PLEX 0
Enter
0
for V-Plex (polling loop) devices. Enter
1
for (ECP) relay modules (4204/4204CF).
Press [
✱
] to continue.
02 V-PLEX ZONE #
000
For polling loop trigger outputs (4101SN), enter the protection zone number (001-032) linked to each output,
if used. Be sure to enroll the module’s serial number (see Zone Programming).
Press [
✱
] to continue.
02 ECP ADDRESS
00
If you selected
1
(4204/4204CF), enter the actual module's address
(01-15)
as set by its DIP switches. Up
to 8 4204/4204CF modules can be installed in a system.
Press [
✱
] to continue.
02 MODULE RELAY#
0
For 4204 Relay Outputs, enter the specific relay number on that module (
1-4
).
For 4204CF outputs,
enter
only module relay number 1 (Output A) or relay number 3 (Output B).
These are the only two
programmable relays on the 4204CF Module.
Press [
✱
] to continue.
The keypad will display the Start and Stop summary screens again.
Press [
✱
] to continue.
When all relays have been programmed, enter
00
at the "ENTER RELAY NO." prompt.
If you are defining a zone list, continue to the next section. If not, enter
00
+ [
✱
] at the next two prompts. You will then be
asked "Quit Menu Mode?" Enter
1
for "Yes,"
0
for "No." Then enter
✱
99
to exit programming completely.
If supervision of the 4204CF Relay Output is desired, enter a response type for that output's corresponding supervisory zone.
This is equal to 600 + [Relay ID No.]. For example, if you are programming Relay ID No. 1, the relay's supervisory zone 601.
Program this zone with response type 05 (Day/Night) in
Zone Programming.
Zone List Programming
After all relays have been programmed, upon entering
00
at the "ENTER RELAY NO." prompt, you are asked to enter a zone
list. If a zone list number was used to start or stop a relay, you must define the zones belonging to that list as follows:
PROMPT
EXPLANATION
ENTER Zn LIST ?
00=QUIT 00
Enter the zone list number
01-15
. Enter
00
to quit.
01 ADD ZONE #
00=QUIT 00
Using 3-digit entries enter each zone to be included in this zone list. Press [
✱
] after you enter each zone
number.
When you have entered all zones, enter
000
.
Press [
✱
] to continue.
01 Del Zn LIST ?
1=YES 0=NO
0
Enter
0
to save this zone list. Enter
1
to delete it.
01 DEL ZONES ?
1=YES 0=NO
0
Enter
1
to delete one or more zones in that zone list. Enter
0
if no changes are necessary. If you enter 1,
the following screen appears; otherwise, the "Enter Zone LIST" prompt reappears.
01 Zn to DELETE ?
00=QUIT 01
Enter each zone number to be deleted from the zone list, pressing [
✱
] after each number.
VIEW Zn LIST ?
00=QUIT 00
This display appears if you pressed
00
at the “Enter Zone LIST” prompt. Enter the zone list number that you
wish to view.
Press [
✱
] to continue.
01 ASSIGNED ZONE
00=QUIT 00
Press [
✱
] to scroll through all zones in that list. Enter
000
+[
✱
] to quit.
Press
[1]
to exit Menu Mode.
Press
✱
99
to exit Program Mode.