LYNXR-I Installation and Setup Guide
- 19 -
Zone Response Type Definitions
Type 07
24-hour
Audible
Alarm
Zone type 07 is usually assigned to a zone containing an Emergency button
(audible emergency).
Zone Characteristics:
•
Sends a report to the central station, and provides alarm sounds
externally and at the keypad.
Type 08
24-hour
Auxiliary Alarm
Zone type 08 is usually assigned to a zone containing a button for use in
personal emergencies or to a zone containing monitoring devices (i.e.: water
or temperature sensors, etc.).
Zone Characteristics:
•
Sends a report to the central station and provides an alarm sound at the
keypad. (No bell output is provided and there is no keypad timeout.)
5806/5807/5808
01000-020-V0
Type 09
Supervised
Fire
Zone type 09 can be assigned to any wireless zone used as a fire
zone. This zone type is always active and cannot be bypassed.
Zone Characteristics
:
•
Bell output will pulse when this zone type is alarmed.
Type 10
Interior w/Delay
Zone type 10 is bypassed when the panel is armed in the STAY or STAY NO
DELAY mode.
Zone Characteristics
:
•
Entry delay #1 (with programmed entry time) when armed in the AWAY
mode.
•
Entry delay begins whenever sensors in this zone are violated, regardless
of whether an entry/exit delay zone was tripped first.
•
No entry delay when armed in the AWAY NO DELAY mode.
•
Exit delay regardless of the arming mode selected.
Type 20
Arm–Stay
Zone type 20 is a special-purpose zone type used with 5800 Series wireless
pushbutton units.
Zone Characteristics:
•
Exit delay regardless of the arming mode selected.
•
System is armed in the STAY mode when the zone is activated.
•
Zone number is sent to the central station as a user number when arming
or disarming.
Type 21
Arm–Away
Zone type 21 is a special-purpose zone type used with 5800 Series wireless
pushbutton units.
Zone Characteristics
:
•
System is armed in the AWAY mode when the zone is activated.
•
Zone number is sent to the central station as a user number when arming
or disarming.
Type 22
Disarm
Zone type 22 is a special-purpose zone type used with 5800 series wireless
pushbutton.
Zone Characteristics
:
•
Disarms the system when the zone is activated.
Type 23
No Alarm Response
Zone type 23 can be used on a zone when a Powerline Carrier Device (e.g.,
X10) action is desired, but with no accompanying alarm (e.g., front door light).
Type 24
Silent Burglary
Zone type 24 is usually assigned sensors or contacts on exterior doors and
windows where bells and/or sirens are NOT desired.
Zone Characteristics
:
•
Instant alarm, with NO audible indication when is armed in the AWAY,
STAY, STAY NO DELAY, or AWAY NO DELAY mode.
•
Report sent to the central station.
Note:
Keypad beeps if the zone is faulted when system is disarmed and Chime mode is
on.