Interactive Menu Mode Programming
(
✻
56,
✻
80,
✻
81,
✻
83,
✻
84,
✻
85)
Press
[
✻
]
+
interactive mode No.
(i.e.,
✻
56). The keypad will display the first of a series of prompts. A detailed
procedure (with displays of prompts) is provided in later sections of this manual.
Interactive Mode
Used to Program
✻
56 Enhanced Zone Programming Mode
Zone characteristics, report codes, and serial numbers
✻
80 Device Programming Menu Mode
Powerline Carrier Devices
✻
81 Zone List Menu Mode
Zone Lists for powerline carrier activation
✻
83 Enhanced Sequential Mode
5800 Series transmitter serial numbers
✻
84 Assign Zone Voice Descriptors
Voice descriptors for each zone
✻
85 Record Custom Voice Descriptors
Up to 5 custom voice descriptors for zones
Loading Factory Defaults
To load the factory defaults, enter the Programming mode, press
✻
97, then press number 1, 2, 3, or 4 to
select from default tables
1-4 at the back of this manual, or press “0” if you are not selecting a default table.
If a default table is loaded, any data that has already been programmed into the system will be changed according to the
default table selected!
✻
96
resets all subscriber account numbers and CSID in preparation for an initial download.
Exiting Program Mode
✻
98
inhibits re-entry into the Expert or Voice Prompt Programming modes using the Installer Code.
✻
99
allows re-entry into the Expert Program mode using
Installer Code (4112) + 800
or into the
Voice
Prompt Programming
mode using
Installer Code (4112) + 888
.
Note:
After exiting program mode (or upon power-up), the system takes up to a minute to reset. To bypass the reset
delay, press [#] + [0].
Pass-Thru Programming
This mode allows the Installer to use the LYNXR-I keypad and display to program the communications
device that is connected to the LYNXR-I. Refer to the communications device’s installation instruction to
determine whether this feature is supported.
Entering Pass-Thru Programming mode
1. After power-up, enter the
Installer Code (4112) + 899.
2. Once you have entered Pass-Thru Programming mode “PtP” will be displayed on the keypad.
3. Refer to the Installation Instructions for the LRR/IP Communications Device being installed for
additional programming information.
LYNXR-I will abort this mode:
•
When it receives an abort command from the new communications device.
•
If it fails to communicate with an communications device after 20 attempts.
•
30 minutes after the last key has been pressed.