ADEMCO LYNXR-I 

  

Security 

Systems 

    

    

 

Installation and Setup Guide 

 

 
 
 
 

AWAY

OFF

STAY

AUX

LIGHTS ON

RECORD

LIGHTS OFF

STATUS

TEST

VOLUME

CODE

NO DELAY

BYPASS

PLAY

CHIME

FUNCTION

DELETE

ESCAPE

ADD

SELECT

ARMED

READY

4

5

6

7

8

9

0

#

1

2

3

 

 
 
 
 

 
 
 
 
 
K14114  3/06  Rev. B

Содержание ADEMCO LYNXR-I Security System

Страница 1: ...ity Systems Installation and Setup Guide AWAY OFF STAY AUX LIGHTS ON RECORD LIGHTS OFF STATUS TEST VOLUME CODE NO DELAY BYPASS PLAY CHIME FUNCTION DELETE ESCAPE ADD SELECT ARMED READY 4 5 6 7 8 9 0 1 2 3 K14114 3 06 Rev B ...

Страница 2: ...the hallway outside may not wake up the sleeper if the door is closed Install a smoke detector inside bedrooms where electrical appliances such as portable heaters air conditioners or humidifiers are used Install a smoke detector at both ends of a hallway if the hallway is more than 40 feet 12 meters long Install smoke detectors in any room where an alarm control is located or in any room where al...

Страница 3: ...OGRAMMING MENU MODE 34 81 ZONE LIST MENU MODE 37 83 ENHANCED SEQUENTIAL MODE 38 84 ASSIGN ZONE VOICE DESCRIPTORS 41 85 RECORD CUSTOM VOICE DESCRIPTORS 43 VOICE PROMPT PROGRAMMING 44 REMOTE PROGRAMMING CONTROL DOWNLOADING 48 SYSTEM OPERATION 50 TESTING THE SYSTEM 56 SYSTEM COMMUNICATION 57 TROUBLESHOOTING GUIDE 59 PROGRAMMING DEFAULT TABLES 62 INDEX 65 REGULATORY AGENCY STATEMENTS 68 LIMITATIONS OF...

Страница 4: ...utput 120mA max Steady output for burglary panic Temporal pulse output for fire alarms Long Range Radio Audio alarm verification PROGRAMMING Options stored in EEROM Can be uploaded downloaded or controlled via IBM compatible computer using Compass downloader software and specified HAYES modem Voice Prompt programming mode COMMUNICATION Ademco Low Speed Sescoa Radionics Ademco Express Ademco Contac...

Страница 5: ...back plate to a sturdy wall feeding the field wiring through the appropriate openings in the back plate 5 After wiring connections are made carefully reconnect the ribbon cable to the front assembly PC board connector properly aligning the red wire 6 Snap the front assembly to the back plate so it is secured by the locking tabs LOCKING TABS LOCKING TABS LOCKING TABS RED WIRE MARKING DISCONNECT THI...

Страница 6: ...OUTPUT CIRCUITS ARE POWER LIMITED PREMISES TELEPHONE 1 2 3 4 8 6 5 11 7 10 12 15 16 13 14 PHONE FUTURE USE FUTURE USE SOUNDERS PLCD AC EARTH GROUND EARTH GROUND INCOMING TELEPHONE LINE RING TIP RING TIP PIEZO 6 14VDC 120mA max e g WAVE2EX 6 14VDC 30mA max DATA OUT SYNC IN POWERLINE CARRIER DEVICES RJ11 8 POS JACK AC AC SYNC COM DATA 9 BELL 07000 009 V1 NOTE USE ONLY THE K10145X10 OR K10145CN TRANS...

Страница 7: ...es to RJ31X terminals 1 grey and 8 brown respectively e Wire the flying leads of a Direct Connect Cord to the control s phone terminals as shown in the diagram or plug into the 8 position jack f Plug the Direct Connect Cord into the RJ31X jack RJ31X 1 2 3 4 5 6 7 8 RING TIP INCOMING PHONE LINE TO PREMISES PHONES TIP RING TIP RING BROWN GREY RED GREEN INCOMING PHONE LINE TO PREMISES PHONES GREEN RE...

Страница 8: ...e Installation Instructions for device that you are installing for additional information The wire run between the LYNXR I and the Communications Device must not exceed ten 10 feet U U U UL L L L The 7845ENT and 7845CV2 have been evaluated by UL for Household Burglary installations The communications modules have not been evaluated for Household Fire installations AlarmNet 7845i L Communications D...

Страница 9: ...t LAN via the appropriate Ethernet connection if applicable 7845GSM 7845i GSM LYNX SUPER HIGH CAPACITY BATTERY OPTIONAL REQUIRED FOR 24 HR BACKUP 7845i GSM 010 V0 GND Z3 OR DATA OUT Z1 Z2 OR DATA IN ECP VOLTAGE INPUT RED BLK GRN YEL RED BLK GRN YEL 4 5 6 3 5 4 4 WIRE CABLE N4632 4 1 2 TB1 LRR IP COMMUNICATIONS PORT LYNXR I CONTROL PANEL NC 12 VDC GND DATA IN DATA OUT LYNX STANDARD CAPACITY BATTERY...

Страница 10: ... BAT LYNXR I CONTROL PANEL RED NC BLK GRN YEL RED BLK GRN YEL 12 VDC GND DATA IN DATA OUT 4 WIRE CABLE N4632 4 LYNX STANDARD CAPACITY BATTERY BATTERY ADEMCO K4362 Connecting AlarmNet 7845CV2 Configuring Long Range Radio and Internet Communication Devices 1 Enable the communications device in programming field 55 and configure alarm reporting and module supervision in programming field 77 2 Program...

Страница 11: ...attery message is displayed and a report is sent to the central station In addition the system will beep once every 45 seconds to audibly indicate a low battery condition press any key to stop the beeping AC Power and Rechargeable Backup Battery Connecting AC Power and backup battery 1 Connect wires from the K10145X10 K10145CN in Canada AC Transformer to terminals 15 and 16 as shown in the wiring ...

Страница 12: ... the battery pack connector from the receptacle on the terminal block PC board 3 Remove the battery pack from the back plate 4 If required replace the tape that secures the battery pack 5 Install a replacement battery pack P N LYNXRCHKIT SC LYNXRCHKIT HC or LYNXRCHKIT SHA into the back plate 6 Install the battery retainer 7 Connect the battery connector to the receptacle on the terminal block PC b...

Страница 13: ...h proper communication and the keypad must be set to the same ID House ID 00 disables all wireless keypads An RF House ID is not necessary for other 5800 Series transmitters the entry should be left at 00 default in those cases Transmitter Supervision Except for some transmitters keypads that may be carried off premises 5804 5804BD 5804BDV and 5804E each transmitter is supervised by a check in sig...

Страница 14: ...tter are cleared This also applies to 5816 and 5817 transmitters that have multiple loops zones 4 Any transmitter that is not entered will not turn off its zone number Go No Go Test Mode 5804E encrypted High Security devices must be activated while the system is in Go No Go Test Mode Refer to the transmitter s installation instructions for complete details The system will confirm enrollment of the...

Страница 15: ... ENROLL AS RF G ree n R ed Yellow AR ME D RE AD Y MESSAGE MIC Notes 1 Loop 4 must be enrolled on the 5801 5804 5804BD 5804BDV and 5804E transmitters whether or not the loop is used 2 5804E encrypted High Security devices must be activated while the system is in Go No Go Test Mode Refer to the transmitter s installation instructions for complete details The system will confirm enrollment of the enc...

Страница 16: ...ming Mode 1 Press both the and keys at the same time within 50 seconds after power is applied to the Control or from exiting Programming mode OR 2 After power up enter the Installer Code 4112 800 to enter Expert Programming mode This method disabled if Program mode is exited using 98 OR enter Installer Code 4112 888 to enter Voice Prompt Programming mode If a different Installer Code has been prog...

Страница 17: ...able selected 96 resets all subscriber account numbers and CSID in preparation for an initial download Exiting Program Mode 98 inhibits re entry into the Expert or Voice Prompt Programming modes using the Installer Code 99 allows re entry into the Expert Program mode using Installer Code 4112 800 or into the Voice Prompt Programming mode using Installer Code 4112 888 Note After exiting program mod...

Страница 18: ...acts on exterior doors and windows Zone Characteristics Instant alarm when armed in AWAY STAY STAY NO DELAY or AWAY NO DELAY mode Type 04 Interior Follower 5890 5890PI 01000 019 V1 Zone type 04 is usually assigned to a zone covering an entry area i e foyer lobby or hallway that one must pass upon entry after faulting the entry exit zone to reach the keypad It provides an instant alarm if the entry...

Страница 19: ...first No entry delay when armed in the AWAY NO DELAY mode Exit delay regardless of the arming mode selected Type 20 Arm Stay Zone type 20 is a special purpose zone type used with 5800 Series wireless pushbutton units Zone Characteristics Exit delay regardless of the arming mode selected System is armed in the STAY mode when the zone is activated Zone number is sent to the central station as a user...

Страница 20: ...d 80 26 Chime by Zone 0 no chimes on fault of any entry exit or perimeter zone when Chime mode is activated 1 yes chimes on fault of those zones assigned to Zone List 3 when Chime mode on This option allows the installer to define the specific zones intended to chime when faulted while the system is in Chime mode If enabled these zones are defined in zone list 3 see 81 Zone List Menu Mode 27 Real ...

Страница 21: ...closing report is sent or at the end of exit delay If Option 2 is selected the external sounder ding occurs immediately after the system receives the RF transmission 39 Power Up In Previous State 0 always power up in a disarmed state 1 assume the system status prior to power down When the system powers up armed an alarm will occur 1 minute after arming if a zone is faulted and any bypassed zones w...

Страница 22: ...er feature enter the phone number here If fewer than 24 digits are entered exit by pressing To clear entries from the field press 46 The telephone message can be terminated acknowledged by pressing any key on the telephone keypad Pressing any key on the local LYNXR I keypad will terminate acknowledge both the follow me and the local reminder announcements Note The follow me reminder announcement w...

Страница 23: ...e message will repeat system system The message can be terminated by pressing any key on the telephone keypad 50 15 Second Dialer Delay Burglary 0 no dialer delay 1 provide 15 second delay of burglary alarm report when armed away If enabled provides delay of burglary report to the central station and allows time for the subscriber to avoid a false alarm transmission The delay applies only to zone ...

Страница 24: ... a 1 in the first box for all the system conditions you want to send to the central station A 0 in the first box disables the report SYSTEM STATUS REPORT CODES 59 68 59 Exit Error Report Code See notes above If the system is armed and an entry exit or interior zone is still open after the exit delay time has expired an alarm will sound at the keypad and external sounder If the system is disarmed b...

Страница 25: ... is sent upon disarming of the system after an alarm condition was reported RESTORE REPORT CODES 70 76 70 Alarm Restore Report Code 1st Digit See notes above Sent when the zone that caused an alarm is restored to its non faulted condition 2nd digit is automatically sent as the 2nd digit of the zone alarm report code programmed in field 56 if expanded or 4 2 reporting is selected 71 Trouble Restore...

Страница 26: ...r is the preferred channel LRR IP Communications Device is the preferred channel First report is sent to the communications device If device fails to deliver report within to deliver report within the time window defined in 77 all following reports go to both LRR IP device and primary phone with no delay When report goes through the LRR IP device LYNXR I stops reporting to primary phone 1 Enable 1...

Страница 27: ...ample To select Alarm Alarm Restore and Open Close enter 9 1 8 to select all events enter 15 Default 3 alarm alarm restore 1 plus trouble trouble restore 2 The system has the ability to record various events in a history log 84 event capacity The types of events to be logged can be selected as indicated At any time the downloader operator can then upload the log and view or print out all or select...

Страница 28: ...e 56 Enhanced Zone Programming Mode section for procedure 80 DEVICE PROGRAMMING MENU MODE Interactive menu mode for programming Powerline Carrier Devices Refer to the 80 Device Programming Menu Mode section for detailed procedure 81 ZONE LISTS MENU MODE Interactive menu mode for programming zone lists for Powerline Carrier Devices Refer to the 81 Zone List Menu Mode section for detailed procedure ...

Страница 29: ... must refer to these instructions or to the Program Form while programming the system because the keypad display does not show prompt titles Instead prompts are indicated by a number letter combination The prompts for 56 are as follows A 02 Zone Number for entering the zone number b Zone Type for entering zone type C Report Code for entering the zone s report code d Input Type for entering the tra...

Страница 30: ... the system responds to faults in that zone Enter the 2 digit zone type for this zone as follows 00 Not Used 08 24 Hr Aux 01 Entry Exit 1 09 Fire without verify 02 Entry Exit 2 10 Interior w Delay 03 Perimeter 20 Arm Stay 04 Interior Follower 21 Arm Away 05 Trouble Day Alarm Night 22 Disarm 06 24 Hr Silent 23 No Alarm Response 07 24 Hr Audible 24 Silent Burglary C rc Report code Enter the report c...

Страница 31: ... other device types four 4 transmissions are required fault restore and fault restore A single beep will sound after the second transmission confirming that the loop and serial number have been captured Following the fourth transmission the system will confirm that the loop number and serial number have been learned and announce the Voice Descriptor for the zone if it is programmed followed by two...

Страница 32: ...sing the 83 Enhanced Sequential Mode Manual entry Enter 1 to advance to Serial number prompt 1b Copy the previous serial number Enter 2 to copy the previous serial number entered Return to Prompt E Enter to return to Loop Number prompt E Enter transmitter later Enter 0 or if you wish to enter the transmitter later using the 83 Enhanced Sequential Mode described later in this manual Notes 1 The pan...

Страница 33: ...3 descriptor 3 will be announced 8 accept word and advance to next zone prompt A entire zone descriptor will be announced Press any other key to repeat the selected word see 84 Assign Zone Voice Descriptors section for vocabulary index Use the 6 or 8 key to advance as described To change the entered index number before pressing 6 or 8 simply press desired 2 digit vocabulary index number If descrip...

Страница 34: ...at must occur to a zone or group of zones zone list in order to activate the device These conditions apply only when a zone list is used The different choices for EVENT are listed below and in the Programming Powerline Carrier Devices paragraph that follows ALARM Device activates upon any alarm in an assigned zone in the zone list FAULT Device activates upon any opening or short in an assigned zon...

Страница 35: ...e to de activate During normal system operation any devices may be manually started by keypad entry of Code 4 n or manually stopped by keypad entry of Code 7 n where n the device number to be controlled Code is required for devices 7 and 8 For devices 1 6 code is not required See User Manual for more information Programming Powerline Carrier Devices While in program mode press 80 to enter Output D...

Страница 36: ...st 1 3 zone list number to be programmed in field 81 0 zone list not used for this device continue return to previous prompt If a zone list will be used to start the device action enter the zone list number at this prompt E zt Start zone type 01 58 zone type to start this device action select only those that are applicable 00 zone type not used for this device continue return to previous prompt If...

Страница 37: ... List Number 01 02 or 03 to program or 00 if no zone lists are used b zz Zone entry to list 01 41 95 96 99 zone numbers to add to zone list accept zone number and enter the next zone number 00 accept zone number s and continue to next prompt Enter each zone number to add to the zone list by first entering the zone number then the key for example 01 02 03 The system will announce the Voice Descript...

Страница 38: ...es The right most column provides a further explanation of the entries Notes 1 Entry of a number other than one specified will give unpredictable results 2 In Enhanced Sequential Mode 4 button type keys will always be enrolled simultaneously They will be stopped at the 4 button boundaries of 26 30 34 and 38 provided the zone is free of a serial number If the first zone of the key has a serial numb...

Страница 39: ...or this transmitter has already been entered however it may still be confirmed viewed or deleted If the transmitter s serial number has not been previously entered you may enter the enroll serial number mode 1A by entering 1 or copy the last serial number that was entered by entering 2 If the transmitter s serial number has been previously entered you may view the present serial number by entering...

Страница 40: ... the Voice Descriptor if it is programmed followed by three beeps and return to Prompt 1A and LC will be displayed No additional transmissions are needed for confirmation Manual Entry Enter the 7 digit serial number printed on the transmitter If you enter an incorrect digit press the key to backup to prompt 1A and start over When all 7 digits are entered press the key If less than 7 digits are ent...

Страница 41: ...digit vocabulary index number of first descriptor word for this zone 6 accept word and advance to descriptor 2 descriptor 2 will be announced 8 accept word and advance to prompt A for next zone Press any other key to repeat the selected word Enter the first word of the descriptor for the selected zone Use the 6 or 8 key to advance as described To change the entered index number before pressing 6 o...

Страница 42: ...DE 67 SILENT POLICE 68 SIX 69 SLIDING 22 SMOKE 23 SOUTH 24 STORAGE 85 SYSTEM T 25 THIRD FLOOR 75 THREE 76 TRANSMITTER 77 TWO U 78 UPSTAIRS 26 UTILITY 79 UTILITY ROOM W 27 WEST 80 WINDOW Y 28 YARD Z 81 ZERO 86 ZONES 29 1ST 30 2ND 31 3RD 70 Custom Word 1 71 Custom Word 2 72 Custom Word 3 73 Custom Word 4 74 Custom Word 5 99 Blank for erasing a previously programmed word SYSTEM WORDS AC LOSS ARMED AW...

Страница 43: ...e upon which this prompt blinks indicating the mode is inactive A 7d Custom descriptor number Enter 7 d Where d 0 4 each representing custom word 70 71 72 73 or 74 respectively Any existing word will be announced Press to start recorder Begin speaking immediately after the third beep Speak the desired word clearly near the microphone Recording stops after 1 5 seconds 6 accept word and ready to rec...

Страница 44: ...ill generate a long rejection beep and repeat the previous voice prompt 3 Phone numbers and account numbers can be left blank by pressing the ADD AWAY key without entering any data 4 LYNXR I automatically saves phone and account number data once all available digits are entered ENTERING VOICE PROMPT PROGRAMMING 1 Power up the control and enter the Installer Code 4 1 1 2 8 8 8 2 Once you have enter...

Страница 45: ... Press SELECT Select delay door location See 1 Press SELECT Activate transmitter twice Press ADD System announces descriptors for the programmed sensor 1 Delay Door Location Front Basement Back Sliding Side Hall Garage Kitchen Patio To add a Window Motion Detector or Fire Detection Sensor Select Add Sensors Press SELECT Select sensor type See 2 Press SELECT Select sensor location See 3 Press SELEC...

Страница 46: ...CT Activate transmitter twice Press ADD System announces the key number LYNXR I automatically saves phone and account number data once all available digits are entered To Add First Central Station Phone Number Select First Central Station Phone Number Press SELECT Enter first central station phone number up to 20 digits Press ADD Enter first central station account number up to 4 digits Press ADD ...

Страница 47: ...ss SELECT Enter second central station account number up to 4 or 10 digits Press ADD Refer to the LYNXR I Programming Default Tables to view the complete set of Template default table selections To Program a Template Default Table Select Templates Press SELECT Select template See 6 Press SELECT 6 Template selections Template 1 Template 2 Template 3 Template 4 To Enter Expert Programming Mode Once ...

Страница 48: ...ystem compromising information Equipment required to download to a system at the premises An IBM PC compatible computer and appropriate interconnecting cables Either a HAYES brand SMARTMODEM 1200 Level 1 2 or higher external or Level 1 1 or higher with 4 position DIP switch internal style a HAYES brand Optima 336 external a HAYES brand Optima 24 Plus FAX96 or an Ademco CIA Modem Compass Downloader...

Страница 49: ...pad will become inactive and will display CC 2 The keypad will become active after the download communication is terminated 3 The detailed operation of the download functions is covered in the installation instructions for the Compass Downloader for Windows Remote Programming Advisory Notes Keypad entries are ignored during the time interval stated above A copy of the program downloaded may be pri...

Страница 50: ...rity codes permit access to the system for arming disarming etc The Installer Code can disarm the system only if it was used to arm it In addition the Installer Code cannot disarm the system if it was armed by pressing and holding a Quick Arm button The Babysitter Code User Code No 7 can disarm the system only if it was used to arm it In addition the Babysitter Code cannot disarm the system if it ...

Страница 51: ... messages To arm in STAY mode STAY or installer code 3 To restart exit delay STAY applies only if system is armed in Stay mode To arm in AWAY mode AWAY or installer code 2 To arm with NO DELAY AWAY or STAY NO DELAY To arm if Quick Arm is programmed AWAY or STAY hold down for at least 2 seconds To disarm the system and silence alarms OFF Note During Exit Delay or when an Alarm Condition exists the ...

Страница 52: ...NTER CODE every three 3 seconds for the next eight 8 seconds During this period the panel will wait for a valid User Code to be entered If a valid User Code is not entered or the eight 8 second period expires a modem tone will be generated for remote programming Compass Downloading If a valid User Code has been entered the control will announce the current system status and or beeping sounds Keypa...

Страница 53: ...ring one of the valid AVM commands shown in the table below The session may be extended 5 minutes without changing the operating mode by pressing the 7 key on the touch tone phone Selecting another operating mode also resets the session an additional 5 minutes During the last minute of the 5 minute session the LYNXR I generates two beeps every 30 seconds to alert the Central Station operator that ...

Страница 54: ...local LYNXR I keypad will terminate acknowledge the message The system will dial the secondary phone number a maximum of eight times The Follow Me alarm functions may be triggered by a variety of events depending upon the selections made during programming in field 49 Note The follow me system announcement will be terminated if any other event requires the system to dial out or if an audible alarm...

Страница 55: ...n bypassed CHIME Chime feature is activate FAULT A malfunction is discovered in the system or an open is detected in a fire zone or a fault in a day night burglary zone is discovered during a disarmed period Accompanied by a display of the zone number in trouble FIRE A fire alarm or fire fault is present Accompanied by a display of the zone that is in alarm LOW BAT Low battery condition in a wirel...

Страница 56: ...nce alarm sounder s by entering the code and pressing OFF Check entry exit delay zones 2 Check the keypad initiated alarms that are in the system by pressing the Panic key pairs If the system has been programmed for audible emergency the keypad will emit a steady alarm sound and ALARM and zone number will be displayed Silence the alarm by entering the security code and pressing OFF If the system h...

Страница 57: ... the three sets of handshake kissoff frequencies that the panel supports and the different formats that can be sent for each FORMAT HANDSHAKE TRANSMITS DATA KISSOFF TRANSMIT TIME Low Speed 1400Hz 1900Hz 10PPS 1400Hz Under 15 seconds 3 1 Standard report 4 1 4 2 Sescoa Rad 2300Hz 1900Hz 20PPS 2300Hz Under 10 seconds 3 1 Standard report 4 1 4 2 Express 1400 2300Hz DTMF 10 cps 1400Hz Under 3 seconds 4...

Страница 58: ...AC Loss Walk Test etc contain zeroes in the ZZZ location CONTACT ID EVENT CODES Code Definition 110 Fire Alarm 121 Duress 122 Alarm 24 hour Silent 123 Alarm 24 hour Audible 131 Alarm Perimeter 132 Alarm Interior 134 Alarm Entry Exit 135 Alarm Day Night 146 Silent Burglary 150 Alarm 24 Hour Auxiliary 301 AC Power 302 Low System Battery Battery Test Fail 344 RF Jam Detected 353 ECP Communication Sup...

Страница 59: ...P module communication failure displayed on RF Keypad only CA appears if an exit or interior zone contained a fault during closing at the time the Exit Delay ended e g exit door left open but the system was disarmed during the Entry Delay time The alarm sounder and keypad sound continuously but stop when the system is disarmed No message will be transmitted to the central station CC Modem Comm sys...

Страница 60: ...ypad 4a System is in Test mode 4b A transmitter low battery has occurred and is displayed 4c A supervision fault has occurred 4d System low battery 4a Enter Code OFF to exit Test mode 4b Enter Code OFF and replace the battery 4c Check the transmitter indicated Restore communication to the receiver to cancel the condition 4d Replace system battery 5 There is no response to a transmitter in normal o...

Страница 61: ...ight not on Open or faulted zone s Check for faulted zones and make intact or use Bypass arming if desired 4 System doesn t respond to keystrokes on keypad 4a CC displayed 4b d1 displayed 4a System is in communication with downloader at central station 4b System has just been powered and is in its one minute initialization 4a Wait until download session is finished 4b Wait for initialization to fi...

Страница 62: ...econd dialer delay burglary 0 1 0 0 51 Periodic test report 0 3 0 0 52 First test report offset 2 2 2 2 53 Sescoa radionics select 0 0 0 0 54 Lack of usage notification 0 0 0 0 55 Enable Disable ECP interface 0 0 0 0 56 Enhanced Zone programming See 56 table See 56 table See 56 table See 56 table 58 RF jam detection 0 0 0 0 59 Exit error report code 1 0 1 1 60 Trouble report code 1 0 1 0 1 0 1 0 6...

Страница 63: ...RF 2 47 04 FRONT DOOR 3 1 1 0 3 RF 2 33 04 BACK DOOR 4 3 1 0 3 RF 2 80 WINDOW 5 10 1 0 3 RF 1 56 MOTION DETECTOR 26 21 1 0 5 BR 3 27 22 1 0 5 BR 2 28 20 1 0 5 BR 4 29 23 0 0 5 BR 1 30 21 1 0 5 BR 3 31 22 1 0 5 BR 2 32 20 1 0 5 BR 4 33 23 0 0 5 BR 1 92 1 0 99 6 1 0 NOTE Zone 2 to 41 are RF zones Zone 92 is Duress Zone 99 is keypad panic 56 ZONE ASSIGNMENT ALARM REPORT CODES FOR TABLE 2 Zone No Zone...

Страница 64: ...NOTE Zone 2 to 41 are RF zones Zone 92 is Duress Zone 99 is keypad panic 80 DEFAULT TABLE APPLIES TO DEFAULT TABLE 4 devices 2 7 have no default values Start Stop Device Number Action Event Zone List Zone Type System Operation Restore of Zone List Zone type System operation 1 2 2 1 2 8 2 33 36 NOTE If using an X10 Powerhouse Security SH10A siren as device 8 you must change the device action defaul...

Страница 65: ... AUX Function 1 Button Paging 27 62 AUX Key 27 Away Mode 51 B Babysitter Code 50 Back Plate 5 Backlighting 20 Backup Battery 11 Backup Reporting 21 Battery Life 14 Bell 70 BR 13 30 Burglary Zones 20 Busy Standby 59 Button Transmitters 13 14 Button Type 30 Button Zones 30 Bypass 55 Bypass Report Code 24 62 Bypass Restore Report Code 25 62 C Callback Number 27 Cancel Report Code 62 Canceled Alarm 24...

Страница 66: ...ssage 55 Message Center 51 Modem Comm 59 Mounting Base 5 Mute System Announcements 51 N No Alarm Response 19 No Delay 51 Number of Reports in Armed Period 27 63 O Open Report Code 25 62 Operator Commands 53 Optima 24 Plus FAX96 Modem 48 Other Features 4 Other Functions 51 P PABX Access Code 21 62 Pager 23 Pager Characters 27 62 Pager Function 52 Pager Message 27 Pager Report Format 23 Paging Featu...

Страница 67: ...ode 51 Stop Recording 51 Stop Zone List 36 Stop Zone Type 36 Supervised Fire 19 Supervised RF 13 30 System Battery 60 System Communication 57 58 System Features 4 System Operation 34 35 50 64 System Power 4 System Words 42 T Technical Support 70 Telco Handoff 48 Temporal Pulse 20 Test Mode 51 56 60 61 Test Report Code 25 62 Test Restore Report Code 62 Testing the System 56 Time and Date 51 Transmi...

Страница 68: ...n Instructions or User s Manual Unauthorized changes or modifications could void the user s authority to operate the equipment Federal Communications Commission FCC Part 68 This equipment complies with Part 68 of the FCC rules On the front cover of this equipment is a label that contains the FCC registration number and Ringer Equivalence Number REN You must provide this information to the telephon...

Страница 69: ... by those beams They cannot detect motion or intrusion that takes place behind walls ceilings floors closed doors glass partitions glass doors or windows Mechanical tampering masking painting or spraying of any material on the mirrors windows or any part of the optical system can reduce their detection ability Passive Infrared Detectors sense changes in temperature however as the ambient temperatu...

Страница 70: ...e Pole Ringer Equivalence 0 6B FCC Registration No 5GBUSA 25623 AL E Contacting Technical Support PLEASE before you call Technical Support be sure you READ THE INSTRUCTIONS Check all wiring connections Determine that the power supply and or backup battery are supplying proper voltages Verify your programming information where applicable Note the proper model number of this product and the version ...

Страница 71: ...OTE USE ONLY THE K10145X10 OR K10145CN CLASS 2 TRANSFORMERS PROVIDED LYNXR I SUMMARY OF CONNECTIONS LOCAL SOUNDER DISABLE SHUNT REMOVE TO DISABLE LYNXR I ALSO COMPLIES WITH THE FOLLOWING CANADIAN STANDARDS ASSOCIATION CSA C22 1 CANADIAN ELECTRICAL CODE PART 1 SAFETY STANDARD FOR ELECTRICAL INSTALLATIONS AND CAN ULC S540 INSTALLATION OF RESIDENTIAL FIRE WARNING SYSTEMS THE LYNXR I CONTROL IS COMPAT...

Страница 72: ...PTION ON THE FACE HEREOF IN NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER S OWN NEGLIGENCE OR FAULT Seller does not represent that the products it sells may not be compromised or circumvented that the p...