– 47 –
Summary Of Audible Notification
Summary Of Audible Notification
Summary Of Audible Notification
Summary Of Audible Notification
*UPPER CASE indicates announcements after pressing
STATUS
once. Lower case indicates announcements after
pressing
STATUS
twice.
SOUND CAUSE
DISPLAY
ANNOUNCEMENT*
INTERRUPTED
Speaker and
external piezo and
bell
FIRE ALARM
FIRE
ALARM
is displayed; zone
number in alarm displayed.
fire alarm + zone voice
descriptor
(Voice descriptor is
interlaced with the siren and
sounds every 45 seconds)
CONTINUOUS
Speaker and
external piezo and
bell
BURGLARY/AUDIBLE
EMERGENCY ALARM
ALARM
is displayed; zone number
in alarm displayed.
alarm + zone voice
descriptor
(Voice descriptor is
interlaced with the siren and
sounds every 45 seconds)
ONE SHORT BEEP
(not repeated)
Speaker and
external piezo
a. SYSTEM DISARM
b. SYSTEM ARMING
ATTEMPT WITH AN
OPEN ZONE.
c. BYPASS VERIFY
a. Green LED on steady
b. The number of the open protection
zone is displayed after pressing
STATUS
.
c. Numbers of the bypassed
protection zones are displayed
(One beep is heard for each zone
displayed).
a. DISARMED–READY TO
ARM
b. DISARMED–NOT READY
TO ARM
c. zones bypassed
ONE SHORT BEEP
(once every 45
secs) Speaker and
external piezo
a. SYSTEM IS IN TEST
MODE
b. LOW BATTERY AT A
TRANSMITTER
c. SYSTEM LOW
BATTERY
d. FAIL TO
COMMUNICATE
a. Opened zone identifications will
appear.
b.
LOW BAT
displayed with zone
number of transmitter.
c.
LOW BAT
displayed with no zone
no.
d.
FC
displayed with no zone no.
a. No announcement
b. low b zone voice
descriptor
c. system low battery
d. check system
TWO SHORT
BEEPS
Speaker and ext.
piezo
ARM AWAY OR MAXIMUM
AWAY or AWAY + INSTANT
is
displayed. Red ARMED indicator is
lit.
ARMED AWAY [INSTANT] –
EXIT NOW
THREE SHORT
BEEPS
Speaker and
external piezo
a. ARM STAY OR INSTANT
b. ZONE OPENED WHILE
SYSTEM IS IN CHIME
MODE.
a.
STAY
or
STAY + INSTANT
is
displayed. Red ARMED indicator is
lit.
b.
CHIME
displayed, number of open
protection zone will be displayed if
the Status key is pressed.
a. ARMED STAY [INSTANT]
– EXIT NOW
b. zone voice descriptor
RAPID BEEPING
Speaker and
external piezo
a. TROUBLE
b. MEMORY OF ALARM
a.
FAULT
displayed. Number of
troubled protection zone is
displayed.
b.
FIRE ALARM
or
ALARM
is
displayed; zone number in alarm is
displayed.
a. fault + zone voice
descriptor
b. fire alarm or alarm + zone
voice descriptor
SLOW BEEPING
Speaker and
external piezo
a. ENTRY DELAY
WARNING
b. EXIT DELAY WARNING
a. Exceeding the delay time without
disarming causes alarm.
b.
AWAY
or
AWAY + INSTANT
is
displayed
a. DISARM SYSTEM NOW
b. ARMED [AWAY]
[INSTANT] – EXIT NOW
Содержание ADEMCO LYNXR-EN
Страница 4: ... 4 ...
Страница 59: ... 59 NOTES ...
Страница 60: ... 60 NOTES ...
Страница 61: ... 61 NOTES ...
Страница 62: ... 62 NOTES ...
Страница 63: ... 63 ...