background image

 
 

 

 

 

 

 

    

ADEMCO LYNXR-I 

  Security 

System

 

 

 

User Guide 

 

 
 
 
 
 
 
 

AWAY

OFF

STAY

AUX

LIGHTS ON

RECORD

LIGHTS OFF

STATUS

TEST

VOLUME

CODE

NO DELAY

BYPASS

PLAY

CHIME

FUNCTION

DELETE

ESCAPE

ADD

SELECT

ARMED

READY

4

5

6

7

8

9

0

#

1

2

3

 

 
 
 
 
 
 

 

K14115  3/06  Rev. A 

 

Содержание ADEMCO LYNXR-EN

Страница 1: ...XR I Security System User Guide AWAY OFF STAY AUX LIGHTS ON RECORD LIGHTS OFF STATUS TEST VOLUME CODE NO DELAY BYPASS PLAY CHIME FUNCTION DELETE ESCAPE ADD SELECT ARMED READY 4 5 6 7 8 9 0 1 2 3 K14115 3 06 Rev A ...

Страница 2: ...icating bus if Honeywell has not approved such device for use with your security system Use of any such unauthorized device may cause damage or compromise the performance of your security system and affect the validity of your Honeywell limited warranty When you purchase devices that have been manufactured or approved by Honeywell you acquire the assurance that these devices have been thoroughly t...

Страница 3: ... Clock Calendar 29 Scheduling User Interface 31 Remote Phone Control Feature 36 Speaker Phone Feature 38 FIRE ALARM SYSTEM 40 General Information 40 National Fire Protection Association s Smoke Detector Recommendations 41 Emergency Evacuation 42 SYSTEM FUNCTIONS 43 Security Codes 43 Testing the System 44 Trouble Messages 45 Maintaining Your System 46 SUMMARY OF AUDIBLE NOTIFICATION 47 FCC STATEMEN...

Страница 4: ... 4 ...

Страница 5: ... to manually activate fire personal emergency or silent alarms Refer to the PANIC KEYS section for detailed information Paging feature If programmed by your installer this feature alerts you to certain system conditions by displaying code numbers that indicate the type of condition that has occurred In addition pressing the AUX key can send a predefined message to your pager if programmed to do so...

Страница 6: ...c activation or deactivation of X10 devices or program events e g alarm clock reminder and latch key Two way voice Allows the central station to listen talk to or conduct two way conversations with individuals on the premises Refer to the TWO WAY VOICE section for detailed information Phone Control Provides a remote interactive phone capability that permits access to the security system from any o...

Страница 7: ...system by using the NO DELAY key in combination with the desired arming key The system also allows you to bypass selected zones before arming the system if desired Refer to the BYPASSING PROTECTION ZONES section The system also provides a CHIME mode for alerting users to the opening of protected doors and windows while the system is disarmed You must turn on arm the burglary protection portion of ...

Страница 8: ...lice or rescue departments If the Two way Voice Feature has been programmed and an alarm condition is detected the system sends an alarm message to the central station After acknowledgement is received a listen in to follow message is sent to the central station By responding to this message the central station operator can enter commands that allow him to initiate a 5 minute voice session The opt...

Страница 9: ...t required if Quick Arm is active Instead press and hold down the STAY or AWAY key MESSAGE CENTER To record a message FUNCTION RECORD To stop recording before end of 85 secs OFF To play back a message FUNCTION PLAY To skip a message To delete all messages FUNCTION DELETE during message replay VOLUME ADJUSTMENT To adjust message playback announcement volume FUNCTION VOLUME 3 or 6 To mute system ann...

Страница 10: ...enabled by your installer OTHER FUNCTIONS To set the time and date FUNCTION 63 To set scheduling FUNCTION 64 To activate X10 devices 1 6 FUNCTION LIGHTS ON device number To activate X10 devices 7 8 FUNCTION LIGHTS ON device number To deactivate X10 devices 1 6 FUNCTION LIGHTS OFF device number To deactivate X10 dev 7 8 FUNCTION LIGHTS OFF device number To add a user code CODE user no 02 08 user co...

Страница 11: ...ture and location of all occurrences 1 2 3 4 5 6 7 8 9 0 RECORD VOLUME PLAY LIGHTS ON TEST BYPASS LIGHTS OFF CODE CHIME STATUS NO DELAY FUNCTION ARMED READY OFF AWAY STAY AUX 01009 023 V1 ESCAPE DELETE ADD SELECT The keypad also features a built in sounder which will sound during alarms and troubles The keypad also beeps during certain system functions such as during entry exit delay times in Chim...

Страница 12: ...y functions and setting the real time clock Note The system functions described below are for reference only and require additional key entries to activate 1 DISPLAY WINDOW Liquid Crystal Display LCD Displays protection point identification and system status messages and user instructions 2 ARMED INDICATOR RED Lit when the system has been armed STAY AWAY NO DELAY Blinks when armed and fault exists...

Страница 13: ...g protected doors windows and other perimeter protection points and sounds an alarm if one is opened Interior protection is not armed which allows movement within your house without causing an alarm Entrance can be made through an entry delay zone without causing an alarm if the system is disarmed before the entry delay time expires Used to delete messages 16 AWAY ADD KEY Completely arms both peri...

Страница 14: ...ttery condition AC Appears when AC power is present If not displayed the system is operating on backup battery power CHIME Appears when the Chime feature is activated TEST Appears when the system is in Test mode Blinks during the last 5 minutes of test REC Appears when the system is in Recording mode MESSAGE Appears when a message has been recorded and has not yet been played back BYPASS Appears w...

Страница 15: ...tem disarmed not ready to arm message armed away stay instant check system message NOTE The phrases shown in brackets are variable and are announced only if appropriate in the current state of the system Press the STATUS key a second time to announce specific system status Depending on the current state of the system the following phrases may be heard fire alarm zone voice descriptors alarm zone v...

Страница 16: ... exit delay at any time after arming in STAY mode This is useful if you wish to open the entry exit door to let someone in after arming the system and avoids having to disarm the system and then re arm it again To restart exit delay while system is armed in STAY mode Press STAY key Arming In Away Mode Use this mode when no one will be staying on the premises Close all protected perimeter windows a...

Страница 17: ... DELAY AWAY or STAY NO DELAY Your user code See Quick Arming paragraph Quick Arming If Quick Arm was programmed by the installer you do not need to enter the security code to arm the system Instead simply press and hold down the desired arming key for at least 2 seconds The security code must always be used to disarm the system however To arm if Quick Arm is active AWAY or STAY hold down for at le...

Страница 18: ...n exit alarm message is sent to the alarm monitoring company The message EA is displayed on the keypad along with a zone number indicating the faulted zone The alarm will continue to sound until the system is disarmed or timeout ocurs To stop the alarm the system must be disarmed by entering your security code and pressing the OFF key and the message CA is displayed on the keypad indicating that t...

Страница 19: ...lence burglary alarms OFF Your user code During alarm conditions and the entry delay the alarm panel will disarm as soon as the correct user code is entered on the keypad The entry beeps or alarm sound can be silenced by pressing any key however it will restart in 10 seconds if the correct User Code is not entered The READY indicator will light if no alarms have occurred while armed and the keypad...

Страница 20: ...ypassed zone number Wait for these zones to be displayed to be sure that intended zones are bypassed Arm the system as usual when the keypad displays the READY LED on steady Forced Bypass Your system may allow you to easily bypass all open faulted zones without having to enter zone numbers individually Ask your installer if this feature is active To bypass a zone s BYPASS FUNCTION Your user code I...

Страница 21: ...sends an emergency message to the alarm monitoring company and sounds a loud steady alarm at your keypad and at any external sounders that may be connected ALARM plus a zone number are also displayed A personal emergency aux alarm sends an emergency message to the alarm monitoring company and sounds at keypads but not at external sounders ALARM plus a zone number are also displayed A supervised fi...

Страница 22: ...t caused the alarm 101 Open system disarmed 00NN following indicates user number 102 Close system armed 00NN following indicates user number 811 Trouble 00NN following indicates the zone that caused the trouble 0NNN First digit is always 0 followed by 3 digit user or zone number depending on the type of event that occurred If NN 00 it can mean an AC loss has occurred the system battery is low or a...

Страница 23: ...n be triggered manually by pressing the AUX key on the keypad and holding it down for 4 seconds NOTE This is similar to the manual paging feature see Paging Feature for details Reminder Announcements The Follow me reminder announcement is triggered by the scheduler if Reminder Announcements has been chosen as Event Identifier see Scheduling User interface for details NOTE The Follow me reminder ca...

Страница 24: ...cluding the star pound To insert a two 2 second pause press the AUX key 2 If the ESCAPE key is pressed to cancel entry the telephone number must be entered again 3 Pressing any key on a wireless RF keypad will terminate this mode and the Follow Me telephone number must be reentered 3 Enter up to 24 digits After each digit is entered the system will announce the digit and it will be displayed on th...

Страница 25: ...ng commands can be used to override the device activation See your installer for a full explanation of this feature To activate X10 devices 1 6 FUNCTION LIGHTS ON dev no 2 beeps To deactivate X10 devices 1 6 FUNCTION LIGHTS OFF dev no 2 beeps To activate X10 devices 7 8 FUNCTION LIGHTS ON dev no 2 beeps Your user code To deactivate X10 devices 7 8 FUNCTION LIGHTS OFF dev no 2 beeps Your user code ...

Страница 26: ... the end of 85 seconds Press OFF The keypad beeps twice the REC display turns off but the MESSAGE display remains on Additional messages can be recorded as long as there is recording time remaining by repeating the above steps NOTE If you are trying to record a new message and the message center is already full the system will announce END MESSAGE and REC MESSAGE will not be displayed If the messa...

Страница 27: ...el Repeat the key sequence until the desired volume level is achieved To mute system announcements FUNCTION VOLUME OFF When muted no system announcements will be made Recorded messages will be announced though when PLAY is pressed To restore announcement sounding FUNCTION VOLUME 3 or 6 Volume level will be restored to the level that was selected prior to muting the sound NOTE If a wireless keypad ...

Страница 28: ...ldom used but repeatable sequences Arming sequences that involve bypassing zones before arming Device activation sequences Defining the AUX Function The system must be disarmed before defining a function 1 Enter FUNCTION AUX hold down at least 2 seconds until 4 beeps sound Master user code 2 Press the desired command sequence up to 20 keystrokes Press the AUX key between each command in the sequen...

Страница 29: ...r two digit hour then press ADD to accept ESCAPE to quit Hour 12 A The current hour will be displayed with the AM PM indication Enter the 2 digit hour i e 01 12 Press ADD to accept the entry and continue to the AM PM selection Press ESCAPE to exit Clock Calendar mode keypad beeps 4 times 2 The system will announce Enter one for PM zero for AM press ADD to accept ESCAPE to quit AM PM 12 P The curre...

Страница 30: ...01 31 Press ADD to accept the entry and continue to the year setting Press ESCAPE to back up to Month selection 6 The system will announce Enter two digit year press ADD to accept ESCAPE to quit Year 05 The current year will be displayed Enter the last two digits of the year i e 00 99 Press ADD to accept the entry and exit Clock Setting mode keypad beeps 4 times Press ESCAPE to back up to Day sele...

Страница 31: ...not possible to enter the schedule programming mode from a wireless keypad 3 Pressing any key on a wireless RF keypad terminates Scheduling setup 4 It is not possible to enter the schedule programming mode when either FC or CA is displayed on the display Because the keypad display does not show prompt titles you must refer to these instructions while programming the system The prompts are indicate...

Страница 32: ...he Device Number screen Selection 1 is a time driven event that requires a begin and end time 2 Latch Key Report the user is required to enter data up to and include the End Day screen Selection 2 is a window driven event that requires a begin end time 3 Automatic Stay Arming the user is required to enter data up to and include the Begin Day screen Selection 3 is a time driven event that requires ...

Страница 33: ...me am A 1 end time pm P continue return to previous prompt The end hour is a two digit entry To enter the hour 3 press 0 followed by 3 The end hour 00 indicates this schedule does not have a end time Press 0 to select AM or 1 to select PM E xx End Time minute xx end minute 0 to 59 continue return to previous prompt xx Ed End Day xx end day 01 to 17 continue return to previous prompt NOTE See figur...

Страница 34: ...o start of window time In addition a secondary phone number must be programmed in Option 42 3 Automatic Stay Arming Will arm the system automatically and bypass any open zones at a given time It will send a report to the pager and central station indicating system has been auto armed stay plus all bypass reports will have only a start time to send the report time driven NOTES 1 Prior executing aut...

Страница 35: ...ting 09 Do event on next time match every weekday will run continuously remains in schedule after executing 10 Do event on next time match every day of the weekend will run continuously remains in schedule after executing 11 Do event on next time match on the next Monday will run continuously remains in schedule after executing 12 Do event on next time match on the next Tuesday will run continuous...

Страница 36: ...sent The system is in any Test mode During real time clock setting During scheduling setup Panel is in shutdown mode programmed by your installer Panel is in Macro learning mode Remote phone control feature has not been enabled by your installer NOTE If a remote phone session is not granted by the system for any of the reasons identified above a modem tone will be generated before the end of the s...

Страница 37: ... code To remotely activate X10 devices 1 6 4 device no To remotely activate X10 devices 7 8 4 device no Your user code To remotely deactivate X10 devices 1 6 7 device no To remotely deactivate X10 devices 7 8 7 device no Your user code To remotely Bypass zones 6 zone no Your user code To remotely activate Forced Bypass 6 Your user code To remotely check system status To end remote phone session Ha...

Страница 38: ...nouncement is being made or a recorded message is being played back A message is being recorded If the system is in test or sniffer mode AC power is not present The speaker phone will be aborted if A report must be sent An audible alarm or trouble has ocurred AC power is lost Using the Speaker Phone Feature When the LYNXR I is operating in the speaker phone mode the system keypad functions as a te...

Страница 39: ...m AUX NOTES 1 The speaker phone ringer can only be enabled disabled when the speaker phone mode is not active The system will ring once to confirm the ringer is enabled Entering VOLUME AUX a second time will disable the ringer No ring will confirm that the ringer is disabled 2 The speaker phone ringer will not ring when an alarm trouble or entry exit delay are sounding 3 The LYNXR I speaker phone ...

Страница 40: ...problem go to your nearest keypad and press the single panic key or panic key pair assigned as FIRE emergency if programmed by the installer and hold down for at least 2 seconds The alarm will sound 2 Evacuate all occupants from the premises 3 If flames and or smoke are present leave the premises and notify your local Fire Department immediately 4 If no flames or smoke are apparent investigate the...

Страница 41: ...household The equipment should be installed as follows A smoke detector installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each additional story of the family living unit including basements and excluding crawl spaces and unfinished attics In addition the NFPA recommends that you install heat or smoke detectors in the living room dining room bedroom s...

Страница 42: ... floor plan of the building Show windows doors stairs and rooftops that can be used to escape Indicate escape routes for each room Keep these routes free from obstruction and post copies of the escape routes in every room 4 Assure that all bedroom doors are shut while you are asleep This will prevent deadly smoke from entering while you escape 5 Try the door If the door is hot check your alternate...

Страница 43: ...e Babysitter Code is assigned to User 07 Duress Code User 08 This feature is intended for use when you are forced to disarm or arm the system under threat When used the system will act normally but can silently notify the alarm monitoring company of your situation if that service has been provided Duress Code is assigned to User 08 The Duress Code is useful only when the system is connected to an ...

Страница 44: ...y The display will clear when the door or window is closed Walk in front of any interior motion detectors if used and listen for three beeps and or voice descriptors if programmed The identification of the detector should appear on the display when it is activated and its voice descriptor will be announced if programmed The display will clear when no motion is detected Note that if wireless motion...

Страница 45: ...on line with the central station s remote computer The control will not operate while on line Wait a few minutes The display should disappear dI If this remains displayed for more than 1 minute the system is disabled bF Indicates backup LRR GSM IP module communication failure displayed on RF Keypad only CA Indicates a cancelled alarm See Entry Exit Delay section EA Indicates an exit alarm See Entr...

Страница 46: ...ry message display will remain on as a reminder When you replace the weak battery with a fresh one the sensor will send a good battery signal to the control when the sensor is activated opening closing of door window etc To clear the LOW BAT message enter OFF key Your user code When replacing batteries use only those recommended by your installer Alkaline batteries provide a minimum of 1 year of o...

Страница 47: ...ry 45 secs Speaker and external piezo a SYSTEM IS IN TEST MODE b LOW BATTERY AT A TRANSMITTER c SYSTEM LOW BATTERY d FAIL TO COMMUNICATE a Opened zone identifications will appear b LOW BAT displayed with zone number of transmitter c LOW BAT displayed with no zone no d FC displayed with no zone no a No announcement b low battery zone voice descriptor c system low battery d check system TWO SHORT BE...

Страница 48: ...ime Fire Alarm zone voice descriptor Fault zone voice descriptor Zones Bypassed Alarm zone voice descriptor Low Battery zone voice descriptor System Low Battery Fire Fault zone voice descriptor Chime AC Loss NOTE If there are no secondary messages the primary status messages will be announced LED Meanings ARMED LED ON System armed Red OFF System disarmed Blinking System armed but a fault exists or...

Страница 49: ...erence to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures If using an indoor antenna have a quality outdoor antenna installed Reorient the receiving antenna until interference is reduced or eliminated Move the radio or television receiver away from the receiv...

Страница 50: ...equipment must also be installed using an acceptable method of connection The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations Repairs to certified equipment should be coordinated by a representative designated by the supplier Any repairs or alterations made by the user to this equipment or equipment malfunctions may give ...

Страница 51: ... result in the loss of your phone lines If the regular phone works correctly after the control communicator has been disconnected from the phone lines the control communicator has a problem and should be returned for repair If upon disconnection of the control communicator there is still a problem on the line notify the telephone company that they have a problem and request prompt repair service T...

Страница 52: ...INFORMATION Your local Honeywell dealer is the person best qualified to service your alarm system Arranging some kind of regular service program with him is advisable Your local Honeywell dealer is Name Address Phone ...

Страница 53: ...NXR I ______________________________________ Other Type of Alarm Burglary Fire Both Installed by Serviced by Name Name Address Address B NOTIFIES Insert B Burglary F Fire Local Sounding Device Police Dept Fire Dept Central Station Name _______________________________________________________________________________ Address Phone C POWERED BY A C With Rechargeable Power Supply D TESTING Quarterly Mo...

Страница 54: ...s Attic Basement Living Room Dining Room Hall F BURGLARY DETECTING DEVICE LOCATIONS Front Door Basement Door Rear Door All Exterior Doors 1st Floor Windows All Windows Interior Locations All Accessible Openings Including Skylights Air Conditioners and Vents G ADDITIONAL PERTINENT INFORMATION Signature Date ...

Страница 55: ...8 45 CC 45 Central Monitoring Station 8 Chime 14 Chime Mode 7 9 11 21 Clock Calendar 29 30 D Day of Week Entries 35 Device Activation 5 Device Descriptions 25 Device Number 33 dI 45 Disarm 9 Disarming The System 19 Display Definitions 14 Displaying Bypassed Zones 20 Duress Code 43 E EA 18 45 Emergency Evacuation 42 End Day 33 End Time 33 Entry Delay 7 18 Event Entries 34 Event Identifier 32 Exit A...

Страница 56: ... Metal Hydride Battery Pack 46 Record 13 Record A Message 9 26 Remote Interactive Phone Capability 36 Restart Exit Delay 9 16 RF Jam Condition 45 S Schedule Number 32 Scheduling 31 Security Codes 6 7 43 Security Functions 9 Servicing Information 52 Silence Alarm 19 40 Silencing Low Battery Warning Tones 46 Silent Emergency Silent Alarm 21 Smoke Detectors 7 Speaker 13 Speaker Phone Feature 38 39 St...

Страница 57: ... injury or death Passive Infrared Motion Detectors can only detect intrusion within the designed ranges as diagrammed in their installation manual Passive Infrared Detectors do not provide volumetric area protection They do create multiple beams of protection and intrusion can only be detected in unobstructed areas covered by those beams They cannot detect motion or intrusion that takes place behi...

Страница 58: ...ER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER S OWN NEGLIGENCE OR FAULT Some states do not allow limitation on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so t...

Страница 59: ... 59 NOTES ...

Страница 60: ... 60 NOTES ...

Страница 61: ... 61 NOTES ...

Страница 62: ... 62 NOTES ...

Страница 63: ... 63 ...

Страница 64: ... K14115 Š K14115 3 06 Rev A 165 Eileen Way Syosset New York 11791 Copyright 2006 Honeywell International Inc www honeywell com security ...

Отзывы: