6 - 10
Data Format Required, Keep Prefix/Suffix
Scanned data is modified according to your data format, and prefixes and
suffixes are transmitted. Any data that does not match your data format
requirements generates an error tone and the data in that bar code is not
transmitted. If you wish to process this type of bar code without generating
an error tone, see
Data Format Non-Match Error Tone
.
Data Format Required, Drop Prefix/Suffix
Scanned data is modified according to your data format. If a data format is
found for a particular symbol, those prefixes and suffixes are not
transmitted. Any data that does not match your data format requirements
generates an error tone. If you wish to process this type of bar code without
generating an error tone, see
Data Format Non-Match Error Tone
Choose one of the following options.
Default = Data Formatter On, Not
Required, Keep Prefix/Suffix.
Data Format Non-Match Error Tone
When a bar code is encountered that doesn’t match your required data for-
mat, the scanner normally generates an error tone. However, you may
want to continue scanning bar codes without hearing the error tone. If you
scan the
Data Format Non-Match Error Tone Off
bar code, data that
doesn’t conform to your data format is not transmitted, and no error tone
* Data Formatter On,
Not Required,
Keep Prefix/Suffix
Data Formatter On,
Not Required,
Drop Prefix/Suffix
Data Format Required,
Keep Prefix/Suffix
Data Format Required,
Drop Prefix/Suffix
Содержание 1900GHD-2
Страница 1: ... Xenon 1900 1902 Area Imaging Scanner User s Guide ...
Страница 14: ...CCB01 010BT Base Part Number Serial Number and Revision Information location Compliance Label locations ...
Страница 60: ...2 26 ...
Страница 82: ...3 22 Quantity Codes 1 0 3 2 4 6 5 7 8 9 ...
Страница 91: ...3 31 1 0 2 3 6 7 5 4 8 9 Save ...
Страница 226: ...8 20 ...
Страница 230: ...9 4 ...
Страница 236: ...10 6 ...
Страница 311: ...Sample Symbols Aztec MaxiCode Micro PDF417 Package Label Test Message Test Message ...
Страница 312: ...Programming Chart 1 0 2 3 6 7 5 4 8 9 ...
Страница 314: ...Honeywell Scanning Mobility 9680 Old Bailes Road Fort Mill SC 29707 Xenon UG Rev D 10 11 ...