6 - 8
Miscellaneous Commands
Suppress characters
FB Suppress all occurrences of up to 15 different characters, starting at the
current cursor position, as the cursor is advanced by other commands.
When the FC command is encountered, the suppress function is
terminated. The cursor is not moved by the FB command.
Syntax = FBnnxxyy . .zz where nn is a count of the number of
suppressed characters in the list, and xxyy .. zz is the list of characters
to be suppressed.
Stop suppressing characters
FC Disables suppress filter and clear all suppressed characters.
Syntax =
FC.
Replace characters
E4 Replaces up to 15 characters in the output message, without moving
the cursor. Replacement continues until the E5 command is
encountered.
Syntax = E4nnxx
1
xx
2
yy
1
yy
2
...zz
1
zz
2
where nn is the
total count of of the number of characters in the list (characters to be
replaced plus replacement characters); xx
1
defines characters to be
replaced and xx
2
defines replacement characters, continuing through
zz
1
and zz
2
.
Stop replacing characters
E5 Terminates character replacement.
Syntax = E5.
Compare characters
FE Compare the character in the current cursor position to the character
“xx.” If characters are equal, move the cursor forward one position.
Syntax = FExx where xx stands for the comparison character’s hex
value for its ASCII code.
Refer to the
ASCII Conversion Chart (Code Page 1252),
page A-4 for decimal, hex and character codes.
Compare string
B2 Compare the string in the input message to the string “s.” If the strings
are equal, move the cursor forward past the end of the string. Syntax
= B2nnnnS where nnnn is the string length (up to 9999), and S consists
of the ASCII hex value of each character in the match string. For
example, B2000454657374 will compare the string at the current
cursor position with the 4 character string “Test.”
Refer to the
ASCII Conversion Chart (Code Page 1252),
page A-4 for decimal, hex and character codes.
Check for a number
EC Check to make sure there is an ASCII number at the current cursor
position. The format is aborted if the character is not numeric.
Содержание 1900GHD-2
Страница 1: ... Xenon 1900 1902 Area Imaging Scanner User s Guide ...
Страница 14: ...CCB01 010BT Base Part Number Serial Number and Revision Information location Compliance Label locations ...
Страница 60: ...2 26 ...
Страница 82: ...3 22 Quantity Codes 1 0 3 2 4 6 5 7 8 9 ...
Страница 91: ...3 31 1 0 2 3 6 7 5 4 8 9 Save ...
Страница 226: ...8 20 ...
Страница 230: ...9 4 ...
Страница 236: ...10 6 ...
Страница 311: ...Sample Symbols Aztec MaxiCode Micro PDF417 Package Label Test Message Test Message ...
Страница 312: ...Programming Chart 1 0 2 3 6 7 5 4 8 9 ...
Страница 314: ...Honeywell Scanning Mobility 9680 Old Bailes Road Fort Mill SC 29707 Xenon UG Rev D 10 11 ...