38
Mounting and Connection Instructions MB-Secure 4G IP USB / IP USB Extension
Module
5
Technical data
5.1
Technical data USB-HUB
Nominal operating voltage
12 V DC
Operating voltage range
10.5 V DC to 15 V DC
Power intake with nominal voltage
The total power intake (all USB connections
plus module) must not exceed 990 mA.
– without Ethernet connection
– with Ethernet connection
– per USB port
60 mA
90 mA
max. 300 mA each
Environmental class according to VdS / EN
50131-3
II / Class II
Operation temperature range
-10°C to +45°C
Storage temperature range
-25°C to +70°C
Relative air humidity
max. 75% non-condensing
Weight
85 g
Dimensions of PCB (W x H x T)
121 x 22 x 90
Conformity
The module art. no. 057820 conforms to EN
50131-3, grade 3, class II
CE conformity MB Secure - IP USB communication module
Novar GmbH hereby declares that the intrusion alarm panel MB Secure 0138xx
with the option IP USB communication module part no. 057820 complies with
Directive 2014/30/EU.
The complete text of the EU Declaration of Conformity is available for download on our homepage
https:// www.security.honeywell.de/ in the Service/Download area.
5.1.1 Recognitions
VdS recognition G121801 as option art. no. 057820 for the MB Secure 0138xx
intrusion alarm panel with integrated alarm transmission.