EN
50
MU2H-0501ge23 R1020
V1.00 / 3.5.2018
M-Bus add-on module EWA600C-MBUS
The M-Bus add-on module
EWA600C-MBUS
facilitates communications be-
tween a heat meter and an M-Bus control unit to transfer the measured values.
The measured values of the meter are read out and updated by the M-Bus add-
on module via the optical interfaces periodically, at intervals of 10 minutes.
After intermediate storage in the M-Bus add-on module, the usage data is
transferred to an M-Bus control unit via the M-Bus upon request.
Connection to the M-Bus
The M-Bus cable is installed on the basis of EN 13757-2.
Please note the following instructions:
• Use high-quality spring-loaded terminals or crimp connections suitable for
the cross-sections.
• Avoid unnecessary scanning of the M-Bus.
• Put the M-Bus into operation in one session if possible.
• Ensure the M-Bus has an uninterruptible power supply.
• Avoid switching the M-Bus off.
• Avoid short-circuits in the M-Bus cable during service work and
retrofit
installations.
Voltage supply
The M-Bus add-on module
EWA600C-MBUS
is also equipped with a battery
in addition to any power supply that may be present via the M-Bus connection.
This provides the supply for the add-on module processor if there is no M-Bus
voltage present.
Installation of the M-Bus add-on module
With the heat meter set
(
EW7011BK..
), the M-Bus add-on
module is already pre-
fitted at the
factory.
EW701 with
M-Bus add-on module EWA600C-MBUS
Содержание resideo EW701
Страница 2: ...2 MU2H 0501ge23 R1020 V1 00 3 5 2018 2020 Resideo Techonologies...
Страница 4: ...V1 00 3 5 2018 MU2H 0501ge23 R1020 3...
Страница 218: ...216 MU2H 0501ge23 R1020 V1 00 3 5 2018 Dimensions EWA600C MBUS 78 48 10 8 28 4 34 1...
Страница 219: ...V1 00 3 5 2018 MU2H 0501ge23 R1020 217 Dimensions EWA600C RF 78 48 11 29...
Страница 222: ...220 MU2H 0501ge23 R1020 V1 00 3 5 2018 FUM5HWHEDES EW701...