4-15
dummyhead
dummyhead
TROUBLESHOOTING
3A133
Driver input
overvoltage
(OV2)
Voltage rise caused by
regeneration current
1. PDU (connected with Dr.
H)
DC voltage value rises
suddenly in motor
running and stop status
(abnormal)
Damaged regenerative
resistance circuit
2. PDU (connected with Dr.
H)
Failure state of
regenerative resistance
circuit DTC 3A106 (page
Failure in related battery
3. Battery pack
Failure state of battery
DTC (page 4-6)
Damaged PDU
4. PDU
Replace PDU
3A134
Driver input
undervoltage
(UV2)
Overload operation
1. PDU (connected with Dr.
H)
Current value is 35 A or
more in motor running
status (abnormal)
Lock or overload by driven
system
2. Driven mechanism
Mechanical lock or
excessive overload
Failure in related battery
3. Battery pack
Failure state of battery
DTC (page 4-6)
Damaged PDU
4. PDU
Replace PDU
3A141
FET
overheating
(OT1)
Overload operation
1. PDU (connected with Dr.
H)
Current value is 35 A or
more in motor running
status (abnormal)
High ambient temperature
around product
2. Motor peripheral area
Peripheral temperature
Lock or overload by driven
system
3. Driven mechanism
Mechanical lock or
excessive overload
Improper installation of
PDU on frame
4. PDU
PDU mounting condition
Damaged PDU
5. PDU
Replace PDU
3A142
Motor
overheating
(OT1)
Overload operation
1. PDU (connected with Dr.
H)
Current value is 35 A or
more in motor running
status (abnormal)
High ambient temperature
around product
2. Motor peripheral area
Peripheral temperature
Lock or overload by driven
system
3. Driven mechanism
Mechanical lock or
excessive overload
Improper installation of
PDU on frame
4. PDU
PDU mounting condition
Damaged PDU
5. PDU
Replace PDU
3A172
Power-on to
running
inhibition
POWER button is pressed
ON with START/STOP
switch in START position
1. START/STOP switch
Switch position (START)
Melt sticking or short circuit
of START/STOP switch
2. START/STOP switch
Continuity between
terminals in START/
STOP switch (page 6-8)
Damaged PDU
3. PDU
Replace PDU
DTC
Detecting Item
Failure Condition/
Possible Cause
Verification Item (Check in numerical order)
Applicable Part
Check for
(abnormal symptom)
Содержание GXE2.0H
Страница 8: ...MEMO dummyhead dummyhead ...
Страница 22: ...MEMO dummyhead dummyhead ...
Страница 27: ...4 1 4 dummytext 4 TROUBLESHOOTING TROUBLESHOOTING INFORMATION 4 2 DTC TROUBLESHOOTING 4 6 ...
Страница 42: ...MEMO dummyhead dummyhead ...
Страница 54: ...6 6 dummyhead dummyhead CONTROL UNIT STAYS MOUNT RUBBERS 5 6 3 5 2 9 7 1 3 2 8 1 4 3 3 3 ...
Страница 58: ...MEMO dummyhead dummyhead ...
Страница 67: ...8 1 8 dummytext 8 WIRING DIAGRAMS WIRING DIAGRAMS 8 2 ...
Страница 70: ...MEMO dummyhead dummyhead ...