NO
NO
YES
NO
Replce the AVR unit.
NO
YES
NO
Replce the stator.
NO
YES
NO
Replce the Rotor.
Is the Brush working?
Check " 4-7. CHECKING
BRUSH " .
Replace the brush.
Is the AVR unit working?
Check " 4-8. CHECKING
A.V.R " .
Is the Stator working?
Check " 4-5. CHECKING
STATOR " .
Is the Rotor working?
Check " 4-6. CHECKING
ROTOR " .
4-5. ALTERNATING CURRENT VOLTAGE IS LOW (50
~
80V).
45
Содержание EZ6500CXS
Страница 1: ......
Страница 10: ...L LB Type AC EXTERNAL CHARACTERISTIC CURVES S SB Type AC EXTERNAL CHARACTERISTIC CURVES 10 ...
Страница 11: ...LS Type AC EXTERNAL CHARACTERISTIC CURVES 11 ...
Страница 44: ...4 4 ALTERNATING CURRENT VOLTAGE IS OV 44 ...
Страница 51: ...4 11 WIRING DIAGRAM R S K Type 51 ...
Страница 52: ...RK LS MK Type 52 ...
Страница 53: ...REH CL Type 53 ...
Страница 54: ...M Type 54 ...
Страница 55: ...SB LB Type 55 ...
Страница 56: ...L Type 56 ...
Страница 57: ...62EAB00 2019 Sep ...