3.2.4 ALTERNATOR
1) Remove the wiring from the alternator.
Disconnect the AVR unit connector.
2) Remove the AVR unit from bracket (2).
AVR unit mount bolt (M5-16L) (2)
Remove the brush holder from bracket (2)
Brush holder mount bolt (M5-16L) (1)
3) Set the generator set with the bracket (2) upwards.
4) Remove the nut fixing bracket (2) onto
the mount base with anti-vibration
rubber.
Nut (M10) (2).
5) Remove the bracket (1).
Bolt (M6-165L) (4)
6) Take out stator cover with crows (2
pcs) raised up by using screw driver.
7) Remove the stator.
The stator is heavy.
Be careful do not hit the coil of the stator to the rotor.
Disconnect
Brush holder
AVR
Bracket (2)
Bolt
Bolt
Bracket (2)
Bolt
Nut
Anti-vibration
rubber
31