65
SERVICING YOUR GENERATOR
Battery Charging
The battery is rated at 11.2 Ah (ampere-hours). Charging current
should equal 10% of the battery’s ampere-hour rating. A battery
charger should be used that can be adjusted to deliver 1.1 amps.
1.Connect the battery charger following the manufacturer’s
instructions.
2.Charge the battery 5–10 hours.
3.Clean the outside of the battery and the battery compartment with a
solution of baking soda and water.
Battery Installation
1.Install the battery into the generator.
2.Connect the positive (+) cable to the battery positive (+)
terminal first, and tighten the bolt securely.
3.Slide the battery boot over the positive (+) cable and terminal.
4.Connect the negative (–) cable to the battery negative (–)
terminal, and tighten the bolt securely.
5.Install the battery strap.
6.Install the battery maintenance cover in the reverse order of removal
Never operate the generator with the battery maintenance cover
open, as poor engine and generator performance will result.
The battery gives off explosive
hydrogen gas during normal
operation.
A spark or flame can cause the
battery to explode with enough
force to kill or seriously hurt you.
Wear protective clothing and a face
shield, or have a skilled mechanic
perform the battery maintenance.
36Z376000.book 65 ページ 2014年9月19日 金曜日 午後6時26分
Содержание EU70is
Страница 93: ...90 MEMO 36Z376000 book 90 ページ 2014年9月19日 金曜日 午後6時26分 ...
Страница 185: ...90 NOTES PERSONNELLES 33Z376000 book Page 90 Thursday September 25 2014 10 07 PM ...
Страница 186: ...Honda EU70is BEDIENUNGSANLEITUNG Originalbetriebsanleitung 34Z376000 book Page 1 Thursday September 25 2014 9 59 PM ...
Страница 277: ...90 MEMO 34Z376000 book Page 90 Thursday September 25 2014 9 59 PM ...
Страница 369: ...90 MEMO 3LZ376000 book Page 90 Thursday September 25 2014 10 17 PM ...
Страница 371: ...36Z376000_WIRING_DIAGRAM fm 51 ページ 2014年9月17日 水曜日 午後12時30分 ...