TAKING CARE OF UNEXPECTED PROBLEMS
69
ENGINE LACKS POWER
NO POWER AT THE AC RECEPTACLES
Possible Cause
Correction
Air filter restricted.
Clean or replace air filter (see page 56).
Bad fuel; generator stored without
treating or draining gasoline, or
refueled with bad gasoline.
Drain fuel tank (see page 63).
Refuel with fresh gasoline
(see page 19).
Fuel filter restricted, fuel system
malfunction, fuel pump failure,
ignition malfunction, valves stuck, etc.
Take the generator to your servicing
dealer, or refer to the shop manual.
Possible Cause
Correction
Output indicator is OFF, and overload
alarm indicator is ON.
Check AC load. Stop and restart the
engine.
Check the cooling air inlet. Stop and
restart the engine.
Overload alarm indicator blink.
After removing the cause of the
overload, power generation can be
resumed by pressing and holding the
Eco Throttle switch (for more than 3
seconds) (see page 25).
AC circuit protector tripped.
Check AC load and reset circuit
protector (see page 26).
Faulty power tool or appliance.
Replace or repair power tool or
appliance.
Stop and restart the engine.
Faulty generator.
Take the generator to your servicing
dealer, or refer to the shop manual.