BEFORE OPERATION
35
To prevent a possible fire, keep the generator at least 1 meter (3 feet) away from
building walls, vehicles, and other equipment during operation. Do not place
flammable objects close to the engine or exhaust.
Before beginning your pre-operation checks, be sure the generator is on a level
and firm surface and the engine switch is in the OFF position.
Check the Engine
• Before each use, look around and underneath the engine for signs of oil or
gasoline leaks.
• Check the engine oil level (see page 37). A low engine oil level will cause the
Oil Alert system to shut down the engine.
• Check the air filters (see page 38). Dirty air filters will restrict air flow to the fuel
system, reducing engine and generator performance.
• Check the fuel level (see page 19). Starting with a full tank will help to
eliminate or reduce operating interruptions for refueling.
AC Appliance and Power Cord
Before connecting an AC appliance or power cord to the generator:
• Use grounded 3-prong extension cords, tools, and appliances, or double-
insulated tools and appliances.
• Inspect cords and plugs, and replace if damaged.
• Make sure that the appliance is in good working order. Faulty appliances or
power cords can create a potential for electric shock.
• Make sure the electrical rating of the tool or appliance does not exceed the
rated power of the generator or the receptacle being used.
• Do not exceed the current limit specified for any one receptacle.
• When an extension cable is required, be sure to use a tough rubber sheathed
flexible cable (IEC 245 or equivalent).
When using an extension cable the resistance value shall not exceed 1.5 Ω.
Содержание EU32i
Страница 3: ......
Страница 16: ...GENERATOR SAFETY 13 SOCKET CAUTION DO NOT OVER FILL DO NOT TIP ...
Страница 78: ...TECHNICAL INFORMATION 75 Receptacle Type Shape Plug F G IT GROUND PIN GROUND PIN GROUND PIN ...
Страница 80: ...WIRING DIAGRAM SCHÉMA DE CABLAGE SCHALTPLAN DIAGRAMMA DEI COLLEGAMENTI ...
Страница 82: ......
Страница 83: ......