SERVICING YOUR GENERATOR
55
ENGINE OIL CHANGE
Drain the oil while the engine is warm to assure rapid and complete draining.
1. Turn the engine switch to the OFF position (see page 40) to reduce the
possibility of fuel leakage.
2. Loosen the maintenance cover screw and remove the maintenance cover
3. Place a suitable container next to the engine to catch the used oil.
4. Remove the oil filler cap, and drain the oil into the container by tipping the
engine toward the oil filler neck.
Improper disposal of engine oil can be harmful to the environment. If you change
your own oil, please dispose of the used oil properly.
Do not discard it in a trash bin, dump it on the ground, or pour it down the drain.
5. With the generator in a level position, fill with the recommended oil to the
upper limit. Do not overfill.
• “Upper limit” means the oil exists to the oil filler neck. Refer to "ENGINE OIL
Maximum oil capacity:
15 oz (0.46 L)
6. Reinstall the oil filler cap securely.
7. Reinstall the maintenance cover and tighten the maintenance cover screw
securely.
Wash your hands with soap and water after handling used oil.
OIL FILLER NECK
UPPER LIMIT
(The oil exists to
the oil filler neck.)
OIL FILLER CAP
Содержание EU3200i
Страница 14: ...GENERATOR SAFETY 12 ...
Страница 98: ...96 MEMO ...