57
SERVICING YOUR GENERATOR
Battery Removal
WARNING:
Battery posts, terminals, and related accessories contain
lead and lead components.
Wash hands after handling.
2. Remove the battery holder band.
3. Remove the negative (–) cable from the battery negative (–) terminal,
and then remove the positive (+) cable from the battery positive (+)
terminal.
4. Remove the battery and the battery rubber from the battery tray.
1. Remove the four 6 mm
cap nuts, and remove the
front cover.
6 mm CAP NUTS
FRONT COVER
COLLAR (4)
POSITIVE (+) CABLE
BATTERY HOLDER BAND
NEGATIVE (–) CABLE
BATTERY RUBBER
31ZT76331.book Page 57 Friday, February 23, 2018 2:59 PM