8-13
dummyhead
dummyhead
GENERATOR/CHARGING SYSTEM
GENERATOR INSPECTION
MAIN WINDING
Remove the control panel (page 8-6).
Disconnect the generator wire harness 5P connector
from the inverter unit.
Measure the resistance between the terminals of the
connector
according to the table below.
SUB WINDING
Remove the control panel (page 8-6).
Disconnect the generator wire harness 5P connector
from the inverter unit.
Measure the resistance between the terminals of the
connector
according to the table below.
EXCITER WINDING
Remove the control panel (page 8-6).
Measure the resistance between the terminals of the
connector
according to the table below.
Terminal number
Resistance
1 – 2
1.4 – 2.1
Ω
1 – 3
1.4 – 2.1
Ω
2 – 3
1.4 – 2.1
Ω
Terminal number
Resistance
4 – 5
0.3 – 0.5
Ω
Terminal number
Resistance
1 – 3
0.5 – 0.9
Ω
Содержание EU10iT1
Страница 15: ...MEMO dummyhead dummyhead ...
Страница 33: ...MEMO dummyhead dummyhead ...
Страница 47: ...MEMO dummyhead dummyhead ...
Страница 53: ...MEMO dummyhead dummyhead ...
Страница 55: ...6 2 dummyhead dummyhead FUEL SYSTEM FUEL SYSTEM TOOL Float level gauge 07401 0010000 ...
Страница 67: ...MEMO dummyhead dummyhead ...
Страница 69: ...8 2 dummyhead dummyhead GENERATOR CHARGING SYSTEM GENERATOR CHARGING SYSTEM TOOL Flywheel puller 07935 8050004 ...
Страница 100: ...12 1 12 dummytext 12 MUFFLER MUFFLER REMOVAL INSTALLATION 12 2 ...
Страница 115: ...MEMO dummyhead dummyhead ...
Страница 130: ...16 1 16 dummytext 16 WIRING DIAGRAM HOW TO READ A WIRING DIAGRAM RELATED INFORMATION 16 2 WIRING DIAGRAM 16 3 ...