OTHER ELECTRICAL
Remove the bolts and R/L. side covers.
Remove the mounting bolts and remove the control box as an assembly with the control panel.
Installation is reverse order of removal.
• Route the harnesses properly (page 2-4, Base shop manual: page 2-12).
TORQUE:
CHOKE CABLE HOLDER
RECESSED BOLT:
2.5 N·m
(0.26 kgf·m, 1.8 lbf·ft)
BOLT (6 x 25 mm) (4)
R. SIDE COVER
CONTROL BOX
L. SIDE COVER
R. CONTROL PANEL GUARD
L. CONTROL PANEL GUARD
WASHER (6 mm) (4)
BOLT (6 x 12 mm) (3)
GROUND BOLT (6 x 16 mm)
SH type shown: