11-2
dummyhead
dummyhead
OTHER ELECTRICAL
OTHER ELECTRICAL
CONTROL BOX REMOVAL/INSTALLATION
Remove the following:
– Maintenance cover/center beam
(Base shop manual: page 5-2)
– Fuel tank (Base shop manual: page 6-4)
– Air cleaner (Base shop manual: page 6-6)
– Generator end cover (Base shop manual: page 5-2)
Open the harness band (1).
Disconnect the connector (2).
Remove the following:
SH, SKH type:
– tapping screw (5 x 14 mm) (3)/harness band (4)
– two washer-screws (4 x 8 mm) (5)/field winding
terminals (6)
– washer-screw (6 x 12 mm) (7)/ground terminal (8)
– two screws (6 x 8 mm) (9)/spring washers (10)/main
winding terminals (11)
LDH type:
– tapping screw (5 x 14 mm) (3)/harness band (4)
– two washer-screws (4 x 8 mm) (5)/field winding
terminals (6)
– washer-screw (6 x 12 mm) (7)/ground terminal (8)
– three screws (6 x 8 mm) (9)/spring washers (10)/
main winding terminals (11)
Open the harness clip (1) and release the wire harness
(2).
Disconnect the 10P connector (3) and 4P connector (4).
(4)
(1)
(2)
(3)
(5)
(6)
(9)
(10)
(11)
(7)
(8)
(4)
(1)
(2)
(3)
(5)
(6)
(9)
(10)
(11)
(7)
(8)
SH, SKH type:
LDH type:
(3)
(1)
(2)
(4)
Содержание EM10000K1
Страница 5: ...1 1 1 dummytext 1 SPECIFICATIONS SERIAL NUMBER LOCATION 1 2 SPECIFICATIONS 1 2 PERFORMANCE CURVES 1 4 ...
Страница 22: ...MEMO dummyhead dummyhead ...
Страница 23: ...7 1 7 dummytext 7 GOVERNOR SYSTEM GOVERNOR ARM CONTROL REMOVAL INSTALLATION 7 2 ...
Страница 40: ...MEMO dummyhead dummyhead ...
Страница 41: ...9 1 9 dummytext 9 IGNITION SYSTEM IGNITION COIL INSPECTION 9 2 ...
Страница 52: ...MEMO dummyhead dummyhead ...
Страница 58: ...MEMO dummyhead dummyhead ...