OPERATION
3. Switch ON the AC circuit breaker.
4. Plug in the appliance.
Most motorized appliances require more than their rated wattage
for startup.
5. Turn on the appliance.
Do not exceed the current limit specified for any of the receptacles.
If an overloaded circuit causes the AC circuit breaker or AC circuit
protector to switch OFF, reduce the electrical load on the circuit, wait a
few minutes and then reset the AC circuit breaker or AC circuit
protector.
If the generator is overloaded and the internal circuit is overheated,
current to the connected appliance(s) may shut off, even though the
AC circuit breaker stays ON and the engine keeps running.
Stop the engine and correct the problem. Allow the generator to cool
for a few minutes, and then restart the engine (see page 26).
AC CIRCUIT PROTECTORS
AC CIRCUIT BREAKER
PLUG
*: Except EB4000X
*
ON